The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Solid‐State Gas Sensors: A Review
Open accessAbstract
During the past three decades, gas sensors based either on the surface characteristics or the bulk electrolytic properties of ceramics, have been the subject of extensive research and development. The application of these sensors range from air‐to‐fuel ratio control in combustion processes such as in automotive engines and industrial furnaces to the detection of leakage of inflammable and toxic gases in domestic and industrial environments. While the solid‐state physical sensors, measuring pressure, temperature, and other physical parameters have been commercially successful, less success has been achieved by their chemical analogs, to measure moderate to very low concentrations of gases of importance. These gases include: , , , , , , propane, methane, ethanol, and so on. The semiconductor‐based chemical sensors owe their popularity to their small size, simple operation, high sensitivity, and relatively simple associated electronics. However, most of them still suffer from nonselectivity. They also have poor shelf‐life and are relatively less stable at higher temperatures. The sensing characteristics and performance of some of the solid‐state gas sensors are reviewed in this paper, together with their sensing mechanism, which still is a gray area and has not been fully understood.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Engelbrecht, R. S., Hsu, H., Amplifiers, P., & Kotzebue, K. L. (1959) · Cited by 1,417
The Chemical Physics of Surfaces
Morrison, S. R., & Estrup, P. J. (1978) · Physics Today · doi:10.1063/1.2995077 · Cited by 708
Cited by
Titanium oxide nanotube arrays prepared by anodic oxidation
Gong, D., Grimes, C. A., Varghese, O. K., Hu, W., Singh, R. S., Chen, Z., & Dickey, E. C. (2001) · Journal of Materials Research · doi:10.1557/jmr.2001.0457 · Cited by 2,041
Metal Oxide Semi-Conductor Gas Sensors in Environmental Monitoring
Fine, G. F., Cavanagh, L. M., Afonja, A., & Binions, R. (2010) · Sensors · doi:10.3390/s100605469 · Cited by 1,477
Protein- and Peptide-Directed Syntheses of Inorganic Materials
Dickerson, M. B., Sandhage, K. H., & Naik, R. R. (2008) · Chemical Reviews · doi:10.1021/cr8002328 · Cited by 960
Quasi-one-dimensional metal oxide materials—Synthesis, properties and applications
Lu, J. G., Chang, P., & Fan, Z. (2006) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2006.04.002 · Cited by 586
First Fifty Years of Chemoresistive Gas Sensors
Neri, G. (2015) · Chemosensors · doi:10.3390/chemosensors3010001 · Cited by 530
Metadata
- Authors
- Azad, A. M., Akbar, S. A., Mhaisalkar, S. G., Birkefeld, L. D., & Goto, K. S.
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 1992-12-01
- Volume
- 139
- Issue
- 12
- Pages
- 3690-3704
- ISSN
- 0013-4651 (ISSN-L)
- 1945-7111
- OpenAlex
- W2112616753
- Cited by
- 395
- References
- 2
- FWCI
- 8.86
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.