Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 230

The DOI matches its Crossref record.

Current Distribution on a Rotating Disk below the Limiting Current

Open access
Newman, John·1966·Journal of The Electrochemical Society

Abstract

The uniform current density on a rotating disk electrode at the limiting current is not achieved at lower currents because the edge of the disk is more accessible than the center as a result of the ohmic potential drop in the solution. The current distribution is calculated for well‐stirred solutions and also for lower rotation speeds where surface overpotential, concentration over‐potential, and ohmic drop are all significant. The current density at the center can vary between 50 and 100% of the average current density, and the ohmic potential drop to the center of the disk is 27.3% greater for the uniform current than for the primary current distribution.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1149/1.2423795

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 230

Metadata

Authors
Newman, J.
Venue
Journal of The Electrochemical Society
Published
1966
Volume
113
Issue
12
Pages
1235
ISSN
0013-4651 (ISSN-L)
OpenAlex
W2012532898
Cited by
230
References
0
FWCI
2.03
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Current Distribution on a Rotating Disk below the Limiting Current. https://app.cochat.ai/papers/10.1149/1.2423795
The paper
Newman, J. (1966). Current Distribution on a Rotating Disk below the Limiting Current. Journal of The Electrochemical Society. https://doi.org/10.1149/1.2423795

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.