Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 172

The DOI matches its Crossref record.

The Use of Elevated Temperature Storage Experiments to Learn about Parasitic Reactions in Wound LiCoO2∕Graphite Cells

Open access
Sinha, N. N., Smith, A. J., Burns, J. C., Jain, Gaurav, Eberman, K. W., Scott, Erik, Gardner, J. P., Dahn, J. R.·2011·Journal of The Electrochemical Society

Abstract

Twenty seven LiCoO 2 /graphite wound prismatic cells containing a variety of electrolyte additives as well as high or low surface area LiCoO 2 were studied during high temperature storage using an automated storage system. The same cells had been previously studied using high precision coulometry. Cells were initially cycled to measure the capacity, charged and then stored for one month at either 40 or 60 °C, then cycled again to measure the reversible and irreversible capacity loss. The process was then repeated. During storage, the open circuit potential was automatically measured every 6 hours. The mechanisms responsible for the voltage drop which occurred during storage and the capacity loss after storage were analysed using a Li inventory model. The voltage drop during storage is caused primarily by parasitic reactions (electrolyte oxidation, transition metal dissolution, etc.) that insert Li into the positive electrode, because the potential of the Li x C 6 electrode is virtually constant on the stage-2/stage-1 plateau even if its Li content changes due to solid electrolyte interface (SEI) growth. The experimental results show that the combination of the electrolyte additive, vinylene carbonate, and low surface area LiCoO 2 minimizes the voltage drop and capacity loss during storage presumably by reducing the amount of electrolyte oxidation occurring at the positive electrode. The same cells had charge endpoint capacity slippages that were closest to 0.00%/cycle during cycling tests monitored with high precision coulometry. Storage experiments, in concert with precision coulometry, allow a clear picture of the effect of additives to be determined.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1149/2.007111jes

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 172

Metadata

Authors
Sinha, N. N., Smith, A. J., Burns, J. C., Jain, G., Eberman, K. W., Scott, E., Gardner, J. P., & Dahn, J. R.
Venue
Journal of The Electrochemical Society
Published
2011
Volume
158
Issue
11
Pages
A1194
ISSN
0013-4651 (ISSN-L)
OpenAlex
W2041030198
Cited by
172
References
0
FWCI
8.47
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Use of Elevated Temperature Storage Experiments to Learn about Parasitic Reactions in Wound LiCoO2∕Graphite Cells. https://app.cochat.ai/papers/10.1149/2.007111jes
The paper
Sinha, N. N., Smith, A. J., Burns, J. C., Jain, G., Eberman, K. W., Scott, E., Gardner, J. P., & Dahn, J. R. (2011). The Use of Elevated Temperature Storage Experiments to Learn about Parasitic Reactions in Wound LiCoO2∕Graphite Cells. Journal of The Electrochemical Society. https://doi.org/10.1149/2.007111jes

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.