A Guide to Ethylene Carbonate-Free Electrolyte Making for Li-Ion Cells
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Li[Ni 0.42 Mn 0.42 Co 0.16 ]O 2 (NMC442)/graphite pouch cells demonstrate superb performance at high voltage when ethylene carbonate (EC)-free electrolytes, using a solvent mixture that is >95% ethyl methyl carbonate (EMC) and between 2 and 5% of an "enabler", are used. The "enablers", required to passivate graphite during formation, can be vinylene carbonate (VC), methylene-ethylene carbonate (MEC), fluoroethylene carbonate (FEC) or difluoro ethylene carbonate (DiFEC), among others. In order to optimize the amount of "enabler" added to EMC, gas chromatography coupled with mass spectrometry (GC-MS) was used to track the consumption of "enabler" during the formation step. Storage tests, electrochemical impedance spectroscopy (EIS), ultrahigh precision coulometry (UHPC), long-term cycling, differential voltage analysis and isothermal microcalorimetry were used to determine the optimum amount of enabler to add to the cells. It was found that the graphite negative electrode cannot be fully passivated when the amount of "enabler" is too low resulting in gas production and capacity fade. Using excess "enabler" can cause large impedance and gas production in most cases. The choice of "enabler" also impacts cell performance. A solvent blend of 5% FEC with 95% EMC (by weight) provides the best combination of properties in NMC442/graphite cells operated to 4.4 V. It is our opinion that the experiments and their interpretation presented here represent a primer for the design of EC-free electrolytes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrolytes and Interphases in Li-Ion Batteries and Beyond
Xu, K. (2014) · Chemical Reviews · doi:10.1021/cr500003w · Cited by 5,566
An Introduction to Error Analysis: The Study of Uncertainties in Physical Measurements
Taylor, J. R., & Thompson, W. (1998) · Physics Today · doi:10.1063/1.882103 · Cited by 2,734
Differential voltage analyses of high-power, lithium-ion cells
Bloom, I., Jansen, A. N., Abraham, D. P., Knuth, J., Jones, S. A., Battaglia, V. S., & Henriksen, G. L. (2005) · Journal of Power Sources · doi:10.1016/j.jpowsour.2004.07.021 · Cited by 585
Dahn, H. M., Smith, A. J., Burns, J. C., Stevens, D. A., & Dahn, J. R. (2012) · Journal of The Electrochemical Society · doi:10.1149/2.013209jes · Cited by 246
Self-citationChalasani, D., Li, J., Jackson, N. M., Payne, M., & Lucht, B. L. (2012) · Journal of Power Sources · doi:10.1016/j.jpowsour.2012.02.004 · Cited by 53
Cited by
High-voltage liquid electrolytes for Li batteries: progress and perspectives
Fan, X., & Wang, C. (2021) · Chemical Society Reviews · doi:10.1039/d1cs00450f · Cited by 980
Electrode Degradation in Lithium-Ion Batteries
Pender, J. P., Jha, G., Youn, D. H., Ziegler, J. M., Andoni, I., Choi, E. J., Heller, A., Dunn, B. S., Weiss, P. S., Penner, R. M., et al. (2020) · ACS Nano · doi:10.1021/acsnano.9b04365 · Cited by 873
Meng, Y. S., Srinivasan, V., & Xu, K. (2022) · Science · doi:10.1126/science.abq3750 · Cited by 751
Zheng, J., Lochala, J. A., Kwok, A., Deng, Z. D., & Xiao, J. (2017) · Advanced Science · doi:10.1002/advs.201700032 · Cited by 524
Markevich, E., Salitra, G., & Aurbach, D. (2017) · ACS Energy Letters · doi:10.1021/acsenergylett.7b00163 · Cited by 502
Metadata
- Authors
- Ma, L., Glazier, S. L., Petibon, R., Xia, J., Peters, J. M., Liu, Q., Allen, J., Doig, R. N. C., & Dahn, J. R.
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 2016-11-17
- Volume
- 164
- Issue
- 1
- Pages
- A5008-A5018
- ISSN
- 0013-4651 (ISSN-L)
- 1945-7111
- OpenAlex
- W2556197166
- Cited by
- 153
- References
- 5
- FWCI
- 7.17
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.