Water Transport and PEFC Performance with Different Interface Structure between Micro-Porous Layer and Catalyst Layer
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
For interfaces between micro-porous layers (MPL) and catalyst layers (CL) made by the gas diffusion electrode (GDE) method, a seamless interface without gaps, shows better performance than that of cells with an interface made by the decal transfer method. With the decal transfer method, the MPL is simply hot-pressed to the CL-membrane assembly. This study investigates the effect of interface structure on cell performance and water transport in the MPL. Water distribution in cross sections of multiple layers were observed by a freezing method, where the cell is cooled below freezing temperature in short time and the water was observed in ice form by Cryo-SEM. The results show that a membrane electrode assembly (MEA) using the GDE method improves cell performance at high current densities. Direct observations by the freezing method and cryo-SEM show that there is no water accumulation at the MPL/CL interface made by the GDE method, while water accumulates at the interface made by the decal method. Other observations show that the water amount inside the MPL increases similarly in the two types of MEA when lowering the temperature, and the difference between the two types of MEA was only the water amount in the interface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Water Transport Mechanisms in PEMFC Gas Diffusion Layers
Owejan, J. P., Owejan, J. E., Gu, W., Trabold, T. A., Tighe, T. W., & Mathias, M. F. (2010) · Journal of The Electrochemical Society · doi:10.1149/1.3468615 · Cited by 204
Cited by
Fan, J., Chen, M., Zhao, Z., Zhang, Z., Ye, S., Xu, S., Wang, H., & Li, H. (2021) · Nature Energy · doi:10.1038/s41560-021-00824-7 · Cited by 635
Pore-scale modeling of complex transport phenomena in porous media
Chen, L., He, A., Zhao, J., Kang, Q., Li, Z.-Y., Carmeliet, J., Shikazono, N., & Tao, W.-Q. (2022) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2021.100968 · Cited by 399
Cold start of proton exchange membrane fuel cell
Luo, Y., & Jiao, K. (2018) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2017.10.003 · Cited by 353
Chen, M., Zhao, C., Sun, F., Fan, J., Li, H., & Wang, H. (2020) · eTransportation · doi:10.1016/j.etran.2020.100075 · Cited by 212
Andersson, M., Beale, S. B., Espinoza, M., Wu, Z., & Lehnert, W. (2016) · Applied Energy · doi:10.1016/j.apenergy.2016.08.010 · Cited by 204
Metadata
- Authors
- Aoyama, Y., Suzuki, K., Tabe, Y., Chikahisa, T., & Tanuma, T.
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 2016
- Volume
- 163
- Issue
- 5
- Pages
- F359-F366
- ISSN
- 0013-4651 (ISSN-L)
- 1945-7111
- OpenAlex
- W2262018469
- Cited by
- 43
- References
- 1
- FWCI
- 1.22
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Water Transport and PEFC Performance with Different Interface Structure between Micro-Porous Layer and Catalyst Layer. https://app.cochat.ai/papers/10.1149/2.0451605jes
- The paper
- Aoyama, Y., Suzuki, K., Tabe, Y., Chikahisa, T., & Tanuma, T. (2016). Water Transport and PEFC Performance with Different Interface Structure between Micro-Porous Layer and Catalyst Layer. Journal of The Electrochemical Society. https://doi.org/10.1149/2.0451605jes
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.