COUNTING CHANNELS: A TUTORIAL GUIDE ON ION CHANNEL FLUCTUATION ANALYSIS
Open accessThe DOI matches its Crossref record.
Abstract
Ion channels open and close in a stochastic fashion, following the laws of probability. However, distinct from tossing a coin or a die, the probability of finding the channel closed or open is not a fixed number but can be modified (i.e., we can cheat) by some external stimulus, such as the voltage. Single-channel records can be obtained using the appropriate electrophysiological technique (e.g., patch clamp), and from these records the open probability and the channel conductance can be calculated. Gathering these parameters from a membrane containing many channels is not straightforward, as the macroscopic current I = iNP o, where i is the single-channel current, N the number of channels, and P o the probability of finding the channel open, cannot be split into its individual components. In this tutorial, using the probabilistic nature of ion channels, we discuss in detail how i, N, and P o max (the maximum open probability) can be obtained using fluctuation (nonstationary noise) analysis (Sigworth FJ. G Gen Physiol 307: 97–129, 1980). We also analyze the sources of possible artifacts in the determination of i and N, such as channel rundown, inadequate filtering, and limited resolution of digital data acquisition by use of a simulation computer program (available at www.cecs.cl ).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Brauchi, S., Orio, P., & Latorre, R. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406773101 · Cited by 375
Self-citationSynaptic plasticity through activation of GluA3-containing AMPA-receptors
Renner, M. C., Albers, E. H., Gutierrez-Castellanos, N., Reinders, N. R., van Huijstee, A. N., Xiong, H., Lodder, T. R., & Kessels, H. W. (2017) · eLife · doi:10.7554/elife.25462 · Cited by 75
Cell Type-Specific Expression of Acid-Sensing Ion Channels in Hippocampal Interneurons
Weng, J.-Y., Lin, Y.-C., & Lien, C.-C. (2010) · The Journal of Neuroscience · doi:10.1523/jneurosci.0582-10.2010 · Cited by 72
Braun, H. A. (2021) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2021.629436 · Cited by 64
Genome mining yields putative disease-associated ROMK variants with distinct defects
(2023) · doi:10.1371/journal.pgen.1011051 · Cited by 7
Metadata
- Authors
- Alvarez, O., Gonzalez, C., & Latorre, R.
- Venue
- Advances in Physiology Education
- Publisher
- American Physiological Society
- Published
- 2002-12
- Volume
- 26
- Issue
- 4
- Pages
- 327-341
- ISSN
- 1043-4046 (ISSN-L)
- 1522-1229
- OpenAlex
- W2159380625
- Cited by
- 128
- References
- 0
- FWCI
- 0.54
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: COUNTING CHANNELS: A TUTORIAL GUIDE ON ION CHANNEL FLUCTUATION ANALYSIS. https://app.cochat.ai/papers/10.1152/advan.00006.2002
- The paper
- Alvarez, O., Gonzalez, C., & Latorre, R. (2002). COUNTING CHANNELS: A TUTORIAL GUIDE ON ION CHANNEL FLUCTUATION ANALYSIS. Advances in Physiology Education. https://doi.org/10.1152/advan.00006.2002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.