A review of water diffusion measurement by NMR in human red blood cells
The DOI matches its Crossref record.
Abstract
This review of water transport measurement in normal human erythrocytes attempts to harmonize discordant results obtained under diverse study conditions with two different techniques: nuclear magnetic resonance (NMR) and radioactive tracer (THO) diffusion. Natural aggregation of red cells into rouleaux appeared to cause most of the variation among results from NMR experiments. The remainder of the discrepancy was attributed to the use of inappropriate mathematical approximations of the two-site exchange equations, differences in blood storage time, and failure to adjust NMR calculations for the nonwater protons. Differences in hematocrit, frequency-magnetic field strength, or NMR pulse technique played no apparent role in the disparity among NMR reports. When these confounding factors were removed, diffusion results obtained by NMR or by influx or bulk diffusion of radioactive tracer agreed within a relatively narrow range of values. These techniques place the mean lifetime of water inside fresh normal human erythrocytes at room temperature (20-25 degrees C) between the extremes of 9.8 and 14 ms, where the uncorrected range was previously 9.8-21.7 ms. This new range of water exchange times corresponds to a range of diffusional permeability between 3.3 and 4.7 x 10(-3) cm/s.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Boxerman, J. L., Bandettini, P. A., Kwong, K. K., Baker, J. R., Davis, T. L., Rosen, B. R., & Weisskoff, R. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340103 · Cited by 594
van Zijl, P. C. M., Eleff, S. M., Ulatowski, J. A., Oja, J. M. E., Uluǧ, A. M., Traystman, R. J., & Kauppinen, R. A. (1998) · Nature Medicine · doi:10.1038/nm0298-159 · Cited by 501
Water diffusion and acute stroke
van Gelderen, P., de Vleeschouwer, M. H. M., DesPres, D., Pekar, J., van Zijl, P. C. M., & Moonen, C. T. W. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310209 · Cited by 410
Multi-component apparent diffusion coefficients in human brain
Mulkern, R. V., Gudbjartsson, H., Westin, C.-F., Zengingonul, H. P., Gartner, W., Guttmann, C. R. G., Robertson, R. L., Kyriakos, W., Schwartz, R., Holtzman, D., et al. (1999) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199902)12:1<51::aid-nbm546>3.0.co;2-e · Cited by 374
A multiparameter analysis of sickle erythrocytes in patients undergoing hydroxyurea therapy
Bridges, K., Barabino, G., Brugnara, C., Cho, M., Christoph, G., Dover, G., Ewenstein, B., Golan, D., Guttmann, C., Hofrichter, J., et al. (1996) · Blood · doi:10.1182/blood.v88.12.4701.bloodjournal88124701 · Cited by 184
Metadata
- Authors
- Herbst, M. D., & Goldstein, J. H.
- Venue
- American Journal of Physiology-Cell Physiology
- Publisher
- American Physiological Society
- Published
- 1989-05-01
- Volume
- 256
- Issue
- 5
- Pages
- C1097-C1104
- ISSN
- 0363-6143 (ISSN-L)
- 1522-1563
- OpenAlex
- W2281989312
- Cited by
- 104
- References
- 0
- FWCI
- 3.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A review of water diffusion measurement by NMR in human red blood cells. https://app.cochat.ai/papers/10.1152/ajpcell.1989.256.5.c1097
- The paper
- Herbst, M. D., & Goldstein, J. H. (1989). A review of water diffusion measurement by NMR in human red blood cells. American Journal of Physiology-Cell Physiology. https://doi.org/10.1152/ajpcell.1989.256.5.c1097
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.