Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 278

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

A volume-sensitive chloride conductance in human colonic cell line T84

Worrell, R. T., Butt, A. G., Cliff, W. H., Frizzell, R. A.·1989·American Journal of Physiology-Cell Physiology

Abstract

The chloride-secreting colonic cell line, T84, was studied under whole cell patch clamp with Cl as the permeant ion in pipette and bath solutions. Transmembrane current was initially small (approximately 50 pA at +100 mV) but increased steadily to average values of 1-3 nA within 5-10 min. The development of this current was associated with visible cell swelling, either without a shape change or with membrane blebbing. Basal, preswelling current levels were restored by the addition of 50-75 mM sucrose to the bath or when pipette osmolality was reduced by an equivalent amount. These findings suggest that an isosmotic pipette filling solution behaves as if it is hypertonic by approximately 60 mosmol/kgH2O to the bath. Currents traversing the swelling-induced conductance were outwardly rectified and showed activation at hyperpolarizing voltages and inactivation at depolarizing voltages. They were Cl selective because the reversal potential for current flow approached the Cl equilibrium potential when bath [Cl] was varied. Under nonswelling conditions (bath solution, 300 mosmol/kgH2O; pipette solution, 240 mosmol/kgH2O), single-channel steps (approximately 9 pA at +100 mV) could be resolved. The single-channel characteristics were similar to the macroscopic currents recorded from swollen cells, showing inactivation at positive voltages and an outwardly rectified current-voltage relation. Summation of these single-channel events yielded currents that were similar to those from swollen cells, implying that activation of multiple channels with these properties is the basis of the swelling-induced Cl conductance. This volume-sensitive Cl conductance would contribute to a regulatory volume decrease when T84 cells swell. Its relation to the secretory Cl conductance in these cells is unknown.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpcell.1989.256.6.c1111

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 278

Metadata

Authors
Worrell, R. T., Butt, A. G., Cliff, W. H., & Frizzell, R. A.
Venue
American Journal of Physiology-Cell Physiology
Published
1989-06-01
Volume
256
Issue
6
Pages
C1111-C1119
ISSN
  • 0363-6143 (ISSN-L)
  • 1522-1563
OpenAlex
W188963926
Cited by
278
References
2
FWCI
8.56
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A volume-sensitive chloride conductance in human colonic cell line T84. https://app.cochat.ai/papers/10.1152/ajpcell.1989.256.6.c1111
The paper
Worrell, R. T., Butt, A. G., Cliff, W. H., & Frizzell, R. A. (1989). A volume-sensitive chloride conductance in human colonic cell line T84. American Journal of Physiology-Cell Physiology. https://doi.org/10.1152/ajpcell.1989.256.6.c1111

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.