The DOI matches its Crossref record.
Transport of iron and other transition metals into cells as revealed by a fluorescent probe
Abstract
Transport of nontransferrin-bound iron into cells is thought to be mediated by a facilitated mechanism involving either the trivalent form Fe(III) or the divalent form Fe(II) following reduction of Fe(III) at the cell surface. We have made use of the probe calcein, whose fluorescence is rapidly and stoichiometrically quenched by divalent metals such as Fe(II), Cu(II), Co(II), and Ni(II) and is minimally affected by variations in ionic strength, Ca(II) and Mg(II). Addition of Fe(II) salts to calcein-loaded human erythroleukemia K-562 cells elicited a slow quenching response that was markedly accelerated by the ionophore A-23187 and was reversed by membrane-permeant but not by impermeant chelators. These observations were confirmed by fluorescence imaging of cells. Other divalent metals such as Co(II), Ni(II), and Mn(II) permeated into cells at roughly similar rates, and their uptake, like that of Fe(II), was blocked by trifluoperazine, bepridil, and impermeant sulfhydryl-reactive organomercurials, indicating the operation of a common transport mechanism. This method could provide a versatile tool for studying the transport of iron and other transition metals into cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Metals in Neurobiology: Probing Their Chemistry and Biology with Molecular Imaging
Que, E. L., Domaille, D. W., & Chang, C. J. (2008) · Chemical Reviews · doi:10.1021/cr078203u · Cited by 2,061
Fluorescent, MRI, and colorimetric chemical sensors for the first-row d-block metal ions
Zhu, H., Fan, J., Wang, B., & Peng, X. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00285g · Cited by 437
Fluorescence analysis of the labile iron pool of mammalian cells
Epsztejn, S., Kakhlon, O., Glickstein, H., Breuer, W., & Cabantchik, Z. I. (1997) · Analytical Biochemistry · doi:10.1006/abio.1997.2126 · Cited by 391
Self-citationBreuer, W., Epsztejn, S., & Cabantchik, Z. I. (1995) · Journal of Biological Chemistry · doi:10.1074/jbc.270.41.24209 · Cited by 326
Self-citationAron, A. T., Ramos-Torres, K. M., Cotruvo, J. A., & Chang, C. J. (2015) · Accounts of Chemical Research · doi:10.1021/acs.accounts.5b00221 · Cited by 280
Metadata
- Authors
- Breuer, W., Epsztejn, S., Millgram, P., & Cabantchik, I. Z.
- Venue
- American Journal of Physiology-Cell Physiology
- Publisher
- American Physiological Society
- Published
- 1995-06-01
- Volume
- 268
- Issue
- 6
- Pages
- C1354-C1361
- ISSN
- 0363-6143 (ISSN-L)
- 1522-1563
- OpenAlex
- W2339241266
- Cited by
- 186
- References
- 0
- FWCI
- 2.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transport of iron and other transition metals into cells as revealed by a fluorescent probe. https://app.cochat.ai/papers/10.1152/ajpcell.1995.268.6.c1354
- The paper
- Breuer, W., Epsztejn, S., Millgram, P., & Cabantchik, I. Z. (1995). Transport of iron and other transition metals into cells as revealed by a fluorescent probe. American Journal of Physiology-Cell Physiology. https://doi.org/10.1152/ajpcell.1995.268.6.c1354
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.