The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Estimating false-positive and false-negative errors in analyses of hormonal pulsatility
Abstract
Previous studies evaluating computer algorithms for endocrine pulse detection have estimated the rate of false-positive pulses in series of purely random variations (i.e., “noise”) and have determined pulse-detection criteria associated with low levels of such false-positive rates. The present study investigates the relationship between the false-positive rate and the sizes of the false-positive and false-negative errors on pulse frequency for series including both pulses and noise. The algorithm used (ULTRA) proceeds by eliminating all peaks of concentration for which either the increment or the decrement does not exceed a threshold expressed in multiples of the local intra-assay coefficient of variation. A total of 336 computer-generated series was analyzed using thresholds of two and three coefficients of variation. The effects of noise level, pulse frequency, pulse amplitude, and presence of a base-line variation on the sizes of the false-positive and false-negative errors were evaluated. The false-positive rate in noise series exceeded the false-positive rate by a 4- to 10-fold factor in series including at least 8 pulses/100 samples. When pulse frequency increased, the false-positive error decreased, but the false-negative error increased. In series with more than 8 pulses/100 samples, the use of thresholds aimed at maintaining the false-positive rate in noise series below 1% resulted in a false-negative error in excess of 20%. In conclusion, for hormonal profiles that include 8 or more pulses/100 samples, the use of pulse-detection criteria tailored to minimize the false-positive rate in noise series may result in an underestimation of pulse frequency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Santen, R. J., & Bardin, C. W. (1973) · Journal of Clinical Investigation · doi:10.1172/jci107454 · Cited by 706
Cited by
Effects of gender and age on the levels and circadian rhythmicity of plasma cortisol
Van Cauter, E. (1996) · Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.81.7.2468 · Cited by 951
Self-citationVan Cauter, E. (2000) · JAMA · doi:10.1001/jama.284.7.861 · Cited by 773
Sleep Loss Results in an Elevation of Cortisol Levels the Next Evening
(1997) · Sleep · doi:10.1093/sleep/20.10.865 · Cited by 745
Self-citationDiabetes: Models, Signals, and Control
Cobelli, C., Dalla Man, C., Sparacino, G., Magni, L., De Nicolao, G., & Kovatchev, B. P. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2036073 · Cited by 511
Modulation of glucose regulation and insulin secretion by circadian rhythmicity and sleep
Van Cauter, E., Blackman, J. D., Roland, D., Spire, J. P., Refetoff, S., & Polonsky, K. S. (1991) · Journal of Clinical Investigation · doi:10.1172/jci115396 · Cited by 448
Self-citation
Metadata
- Authors
- Van Cauter, E.
- Venue
- American Journal of Physiology-Endocrinology and Metabolism
- Publisher
- American Physiological Society
- Published
- 1988-06-01
- Volume
- 254
- Issue
- 6
- Pages
- E786-E794
- ISSN
- 0193-1849 (ISSN-L)
- 1522-1555
- OpenAlex
- W77861502
- Cited by
- 180
- References
- 1
- FWCI
- 7.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Estimating false-positive and false-negative errors in analyses of hormonal pulsatility. https://app.cochat.ai/papers/10.1152/ajpendo.1988.254.6.e786
- The paper
- Van Cauter, E. (1988). Estimating false-positive and false-negative errors in analyses of hormonal pulsatility. American Journal of Physiology-Endocrinology and Metabolism. https://doi.org/10.1152/ajpendo.1988.254.6.e786
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.