CoChat

Experimental reliability of the doubly labeled water technique

Goran, M. I., Poehlman, E. T., Danforth, E. · 1994 · American Journal of Physiology-Endocrinology and Metabolism
Cited by 39

The DOI matches its Crossref record.

Abstract

The experimental reliability of measuring CO2 production rates (rCO2) with the doubly labeled water (DLW) technique was assessed in five young healthy men (23 (DLW) technique was assessed in five young healthy men (23 +/- 4 yr; 66.1 +/- 4.6 kg). To minimize the confounding effects of fluctuations in physical activity and eating patterns on variation in energy expenditure, the subjects lived under sedentary living conditions by confinement to their own room at a Clinical Research Center and were maintained on a fixed and known level of energy intake. rCO2 was determined in duplicate over two identical 9-day study periods after separate loading doses of deuterium and oxygen-18. Turnover rates were determined from multipoint sampling to reduce error from analytical uncertainty. Dilution spaces were determined by both the intercept and plateau methods. The average experimental variation for rCO2 estimates was approximately +/- 8.5% and was not significantly different among three published calculation models that differ in their assumptions regarding the relationship between the dilution spaces of deuterium and oxygen-18. The experimental reliability of +/- 8.5% exceeds theoretical values generated from calculations based on propagation of error from analytical uncertainty. Between subjects, the experimental variation ranged from 1 to 21%, and the half-width of the 95% confidence interval for the precision of rCO2 estimates was high (+/- 12 mol/day) relative to the mean reported value of approximately 16 mol/day.(ABSTRACT TRUNCATED AT 250 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpendo.1994.266.3.e510

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Metadata

Authors
Goran, M. I., Poehlman, E. T., & Danforth, E.
Venue
American Journal of Physiology-Endocrinology and Metabolism
Published
1994-03-01
Volume
266
Issue
3
Pages
E510-E515
ISSN
  • 0193-1849 (ISSN-L)
  • 1522-1555
OpenAlex
W2186418960
Cited by
39
References
0
FWCI
0.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Experimental reliability of the doubly labeled water technique. https://app.cochat.ai/papers/10.1152/ajpendo.1994.266.3.e510
The paper
Goran, M. I., Poehlman, E. T., & Danforth, E. (1994). Experimental reliability of the doubly labeled water technique. American Journal of Physiology-Endocrinology and Metabolism. https://doi.org/10.1152/ajpendo.1994.266.3.e510

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.