Intermittence of blood flow in liver sinusoids, studied by high-resolution in vivo microscopy
The DOI matches its Crossref record.
Abstract
Kupffer cell migration and leukocyte-vessel wall interactions cause temporary slowing and/or stoppage of blood flow through individual liver sinusoids. Such temporal heterogeneity of flow was quantified in anesthetized mice and rats. Video recordings of red blood cell flow in 44 networks containing 8-16 sinusoids each were analyzed for 5- to 10-min periods. Flow was graded "fast," "slow," "stopped," or "reversed" based on red blood cell velocity. The mean numbers of flow changes (between grades) per minute in zone 1 vs. zone 3 were 1.39 vs. 0.78 (mouse) and 1.25 vs. 0.09 (rat). The mean percentage of time for each flow grade differed significantly between zones 1 and 3 and between species. For example, fast flow was present in zone 1 sinusoids for 51% of the time in mice and for 74% in rats; in zone 3 the corresponding numbers were 76 and 95%. Flow stasis was present in zone 1 sinusoids for 19% of the time in mice and for 7% in rats; in zone 3 the corresponding numbers were 2 and 0%. Thus considerable intermittence of perfusion exists, and the flow conditions create very different microenvironments for hepatocytes in zone 1 vs. zone 3.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Liver as an Immunological Organ
Racanelli, V., & Rehermann, B. (2006) · Hepatology · doi:10.1002/hep.21060 · Cited by 1,377
Phenotypic Heterogeneity of the Endothelium: II. Representative Vascular Beds
Aird, W. C. (2007) · Circulation Research · doi:10.1161/01.res.0000255690.03436.ae · Cited by 1,257
Multistep Nature of Metastatic Inefficiency
Luzzi, K. J., MacDonald, I. C., Schmidt, E. E., Kerkvliet, N., Morris, V. L., Chambers, A. F., & Groom, A. C. (1998) · The American Journal of Pathology · doi:10.1016/s0002-9440(10)65628-3 · Cited by 1,243
Self-citationMechanism of hard-nanomaterial clearance by the liver
Tsoi, K. M., MacParland, S. A., Ma, X.-Z., Spetzler, V. N., Echeverri, J., Ouyang, B., Fadel, S. M., Sykes, E. A., Goldaracena, N., Kaths, J. M., et al. (2016) · Nature Materials · doi:10.1038/nmat4718 · Cited by 1,010
Antigen-presenting cell function in the tolerogenic liver environment
Thomson, A. W., & Knolle, P. A. (2010) · Nature Reviews Immunology · doi:10.1038/nri2858 · Cited by 805
Metadata
- Authors
- MacPhee, P. J., Schmidt, E. E., & Groom, A. C.
- Venue
- American Journal of Physiology-Gastrointestinal and Liver Physiology
- Publisher
- American Physiological Society
- Published
- 1995-11-01
- Volume
- 269
- Issue
- 5
- Pages
- G692-G698
- ISSN
- 0193-1857 (ISSN-L)
- 1522-1547
- OpenAlex
- W2286249299
- Cited by
- 126
- References
- 0
- FWCI
- 0.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intermittence of blood flow in liver sinusoids, studied by high-resolution in vivo microscopy. https://app.cochat.ai/papers/10.1152/ajpgi.1995.269.5.g692
- The paper
- MacPhee, P. J., Schmidt, E. E., & Groom, A. C. (1995). Intermittence of blood flow in liver sinusoids, studied by high-resolution in vivo microscopy. American Journal of Physiology-Gastrointestinal and Liver Physiology. https://doi.org/10.1152/ajpgi.1995.269.5.g692
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.