Abstract
The aim of this study was to investigate the effect of pacing parameters on the entrainment of gastric slow waves in patients with gastroparesis. Four pairs of cardiac pacing wires were placed on the serosal surface of the stomach in 13 patients with gastroparesis. After a baseline recording for 30 min, gastric pacing was performed in a number of sessions with different effective parameters, each lasting for 30 min. The following parameters were found to be effective for the entrainment of the gastric slow wave: a pacing frequency 10% higher than the intrinsic gastric slow wave frequency (IGF), 300 ms pulse width, and 4 mA pacing amplitude. A reduction of pacing amplitude from 4 to 2 mA and 1 mA reduced the percentage of entrainment of the gastric slow wave to 79 ± 10% and 50 ± 11%, respectively. Pacing with a pulse width of 30 or 3 ms was not able to entrain the gastric slow wave in any of the patients. An ectopic pacemaker of tachygastria found in three patients was reversed with gastric pacing. It was concluded that gastric pacing at a frequency up to 10% higher than the IGF and with an amplitude of 4 mA and a pulse width of 300 ms is able to completely entrain the gastric slow wave and normalize gastric dysrhythmias in patients with gastroparesis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gastric pacing improves emptying and symptoms in patients with gastroparesis
McCallum, R. W., De Z. Chen, J., Lin, Z., Schirmer, B. D., Williams, R. D., & Ross, R. A. (1998) · Gastroenterology · doi:10.1016/s0016-5085(98)70528-1 · Cited by 415
Self-citationChen, J. D. Z., Lin, Z., Pan, J., & McCallum, R. W. (1996) · Digestive Diseases and Sciences · doi:10.1007/bf02087897 · Cited by 298
Self-citationHuman gastric pacesetter potential
Hinder, R. A., & Kelly, K. A. (1977) · The American Journal of Surgery · doi:10.1016/0002-9610(77)90187-8 · Cited by 288 · cited 1×
“The gastric slow wave is omnipresent, and its frequency in humans is about three cycles per minute (cpm) (2, 12, 16).”
BackgroundSerosal and cutaneous recordings of gastric myoelectrical activity in patients with gastroparesis
Chen, J. D., Schirmer, B. D., & McCallum, R. W. (1994) · American Journal of Physiology-Gastrointestinal and Liver Physiology · doi:10.1152/ajpgi.1994.266.1.g90 · Cited by 181
Self-citationGastric slow wave abnormalities in patients with gastroparesis.
Chen, J., & McCallum, R. W. (1992) · PubMed · Cited by 179
Self-citationHuman gastric myoelectric activity and gastric emptying following gastric surgery and with pacing
Hocking, M. P., Vogel, S. B., & Sninsky, C. A. (1992) · Gastroenterology · doi:10.1016/0016-5085(92)91439-b · Cited by 140 · cited 3×
“This was in agreement with the findings reported in the literature (14).”
BackgroundResultPacing the canine stomach with electric stimulation
Kelly, K. A., & Rc, L. F. (1972) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1972.222.3.588 · Cited by 113 · cited 3×
“A similar maximum driven frequency was previously observed in dogs (18, 21).”
BackgroundGastric electromechanical function and gastric emptying in diabetic gastroparesis
Abell, T. L., Camilleri, M., Hench, V. S., & Malagelada, J. (1991) · European Journal of Gastroenterology & Hepatology · Cited by 107
Gastric Myoelectric Activity in Patients with Chronic Idiopathic Gastroparesis
Bortolotti, M., Sarti, P., Barbara, L., & Brunelli, F. (1990) · Neurogastroenterology & Motility · doi:10.1111/j.1365-2982.1990.tb00015.x · Cited by 89 · cited 1×
“Gastroparesis may be attributed to impaired motor activity and/or impaired myoelectrical activity (1, 3, 6).”
BackgroundElectrical stimulation of gastric electrical control activity
Sarna, S., & Daniel, E. (1973) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1973.225.1.125 · Cited by 82
THE FUTURE OF INTESTINAL PACING
Cullen, J. J., & Kelly, K. A. (1994) · Gastroenterology Clinics of North America · doi:10.1016/s0889-8553(21)00138-2 · Cited by 26
Effect of pacing on small intestinal motor activity and hormonal response in dogs
Reiser, S. B., Weiser, H. F., SCHUSDZIARRA, V., & Siewert, J. R. (1989) · Digestive Diseases and Sciences · doi:10.1007/bf01536336 · Cited by 22
Cited by
Origin and propagation of human gastric slow-wave activity defined by high-resolution mapping
O'Grady, G., Du, P., Cheng, L. K., Egbuji, J. U., Lammers, W. J. E. P., Windsor, J. A., & Pullan, A. J. (2010) · American Journal of Physiology-Gastrointestinal and Liver Physiology · doi:10.1152/ajpgi.00125.2010 · Cited by 280
SALLAM, H., MCNEARNEY, T. A., & CHEN, J. D. Z. (2006) · Alimentary Pharmacology & Therapeutics · doi:10.1111/j.1365-2036.2006.02804.x · Cited by 192
Self-citationTreatment of Diabetic Gastroparesis by High-Frequency Gastric Electrical Stimulation
Lin, Z., Forster, J., Sarosiek, I., & McCallum, R. W. (2004) · Diabetes Care · doi:10.2337/diacare.27.5.1071 · Cited by 188
Self-citationDiabetic Gastroparesis: Diagnosis and Management
Ma, J., Rayner, C. K., Jones, K. L., & Horowitz, M. (2009) · Drugs · doi:10.2165/00003495-200969080-00003 · Cited by 87
Metadata
- Authors
- Lin, Z. Y., McCallum, R. W., Schirmer, B. D., & Chen, J. D. Z.
- Venue
- American Journal of Physiology-Gastrointestinal and Liver Physiology
- Publisher
- American Physiological Society
- Published
- 1998-01-01
- Volume
- 274
- Issue
- 1
- Pages
- G186-G191
- ISSN
- 0193-1857 (ISSN-L)
- 1522-1547
- OpenAlex
- W2131073992
- Cited by
- 180
- References
- 12
- FWCI
- 3.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.