Abnormal cardiac inflow patterns during postnatal development in a mouse model of Holt-Oram syndrome
The DOI matches its Crossref record.
Abstract
Tbx5 del/+ mice provide a model of human Holt-Oram syndrome. In this study, the cardiac functional phenotypes of this mouse model were investigated with 30-MHz ultrasound by comparing 12 Tbx5 del/+ mice with 12 wild-type littermates at 1, 2, 4, and 8 wk of age. Cardiac dimensions were measured with two-dimensional and M-mode imaging. The flow patterns in the left and right ventricular inflow channels were evaluated with Doppler flow sampling. Compared with wild-type littermates, Tbx5 del/+ mice showed significant changes in the mitral flow pattern, including decreased peak velocity of the left ventricular (LV) early filling wave (E wave), increased peak velocity of the late filling wave (A wave), and decreased or even reversed peak E-to-A ratio. The prolongation of LV isovolumic relaxation time was detected in Tbx5 del/+ neonates as early as 1 wk of age. In Tbx5 del/+ mice, LV wall thickness appeared normal but LV chamber dimension was significantly reduced. LV systolic function did not differ from that in wild-type littermates. In contrast, the Doppler flow spectrum in the enlarged tricuspid orifice of Tbx5 del/+ mice demonstrated increased peak velocities of both E and A waves and increased total time-velocity integral but unchanged peak E/A. In another 13 mice (7 Tbx5 del/+, 6 wild-type) at 2 wk of age, significant correlation was found between Tbx5 gene expression level in ventricular myocardium and LV filling parameters. In conclusion, the LV diastolic function of Tbx5 del/+ mice is significantly deteriorated, whereas the systolic function remains normal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Noyan-Ashraf, M. H., Momen, M. A., Ban, K., Sadi, A.-M., Zhou, Y.-Q., Riazi, A. M., Baggio, L. L., Henkelman, R. M., Husain, M., & Drucker, D. J. (2009) · Diabetes · doi:10.2337/db08-1193 · Cited by 575
“* ** ** Untreated Liraglutide EX(9-39) Liraglutide +EX(9-39) Forskolin 0 10 20 30 40 50 60”
MethodSelf-citationZhong, J., Basu, R., Guo, D., Chow, F. L., Byrns, S., Schuster, M., Loibner, H., Wang, X.-H., Penninger, J. M., Kassiri, Z., et al. (2010) · Circulation · doi:10.1161/circulationaha.110.955369 · Cited by 457
Sauvé, M., Ban, K., Momen, M. A., Zhou, Y.-Q., Henkelman, R. M., Husain, M., & Drucker, D. J. (2010) · Diabetes · doi:10.2337/db09-0955 · Cited by 264
Self-citationBasu, R., Oudit, G. Y., Wang, X., Zhang, L., Ussher, J. R., Lopaschuk, G. D., & Kassiri, Z. (2009) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00452.2009 · Cited by 161
“Transthoracic echocardiography was performed noninvasively as described previously using a Vevo 770 high-resolution imaging system equipped with a 30-MHz transducer (RMV-707B; VisualSonics, Toronto, Canada) (56, 57).”
MethodMcVeigh, E. R. (2006) · Circulation Research · doi:10.1161/01.res.0000216870.73358.d9 · Cited by 159
Metadata
- Authors
- Zhou, Y.-Q., Zhu, Y., Bishop, J., Davidson, L., Henkelman, R. M., Bruneau, B. G., & Foster, F. S.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2005-09
- Volume
- 289
- Issue
- 3
- Pages
- H992-H1001
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2082623945
- Cited by
- 53
- References
- 0
- FWCI
- 1.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Abnormal cardiac inflow patterns during postnatal development in a mouse model of Holt-Oram syndrome. https://app.cochat.ai/papers/10.1152/ajpheart.00027.2005
- The paper
- Zhou, Y.-Q., Zhu, Y., Bishop, J., Davidson, L., Henkelman, R. M., Bruneau, B. G., & Foster, F. S. (2005). Abnormal cardiac inflow patterns during postnatal development in a mouse model of Holt-Oram syndrome. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.00027.2005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.