CoChat

Impact of coronary vasa vasorum functional structure on coronary vessel wall perfusion distribution

Gössl, M., Malyar, N. M., Rosol, M., Beighley, P. E., Ritman, E. L. · 2003 · American Journal of Physiology-Heart and Circulatory Physiology
Cited by 97

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Noncoronary vasa vasorum have been described as networks of microvessels in the wall of arteries and veins. However, we have shown, using microcomputerized tomography (micro-CT) imaging methods, that porcine coronary vasa vasorum have a tree-like branching structure similar to the vasculature in general. In this study, we elucidate functional aspects of coronary vasa vasorum perfusion territories. Three pig hearts were injected with radiopaque Microfil via the coronary sinus to fill the left anterior descending coronary arteries (LADs) retrogradely at atmospheric pressure. In three other hearts, LADs were injected antegradely at 100-mmHg pressure via the left main carotid artery. Additionally, six LADs were injected in vivo with a suspension of 100- or 300-μm-diameter microspheres before harvesting of the hearts and injection of the LADs with Microfil. All harvested LADs were scanned intact with micro-CT (20 μm cubic voxels). The spatial density of vasa vasorum (no. of vasa/mm 2) was measured in 20-μm-thick cross sections (at 0.4-mm intervals). Retrogradely injected LADs showed high and uniformly distributed vasa vasorum densities in the adventitia (means ± SE; 5.38 ± 0.09 vs. 3.58 ± 0.1 vasa/mm 2 in antegradely prepared LADs; P < 0.001). Antegradely prepared LADs showed patchy distributed, low-vasa-vasorum-density territories especially on the myocardial side of the coronary artery wall (epicardial density: 4.29 ± 0.13 vasa/mm 2 vs. myocardial density: 2.80 ± 0.1 vasa/mm 2, P < 0.001). Microembolization reduced vasa vasorum densities significantly (100-μm-diameter microspheres: 3.26 ± 0.07 vasa/mm 2, P < 0.05; 300-μm-diameter microspheres: 2.66 ± 0.07 vasa/mm 2, P < 0.001 vs. antegrade controls) and increased the size of low-vasa-vasorum-density territories. We conclude that coronary vasa vasorum are functional endarteries not connected via a plexus. This characteristic may have a significant impact on the spatial distribution of perfusion and drainage of the coronary vessel wall.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpheart.00399.2003

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 97

Metadata

Authors
Gössl, M., Malyar, N. M., Rosol, M., Beighley, P. E., & Ritman, E. L.
Venue
American Journal of Physiology-Heart and Circulatory Physiology
Published
2003-11
Volume
285
Issue
5
Pages
H2019-H2026
ISSN
  • 0363-6135 (ISSN-L)
  • 1522-1539
OpenAlex
W2051786106
Cited by
97
References
2
FWCI
3.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Impact of coronary vasa vasorum functional structure on coronary vessel wall perfusion distribution. https://app.cochat.ai/papers/10.1152/ajpheart.00399.2003
The paper
Gössl, M., Malyar, N. M., Rosol, M., Beighley, P. E., & Ritman, E. L. (2003). Impact of coronary vasa vasorum functional structure on coronary vessel wall perfusion distribution. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.00399.2003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.