The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
In vivo two-photon excited fluorescence microscopy reveals cardiac- and respiration-dependent pulsatile blood flow in cortical blood vessels in mice
Open accessAbstract
Subtle alterations in cerebral blood flow can impact the health and function of brain cells and are linked to cognitive decline and dementia. To understand hemodynamics in the three-dimensional vascular network of the cerebral cortex, we applied two-photon excited fluorescence microscopy to measure the motion of red blood cells (RBCs) in individual microvessels throughout the vascular hierarchy in anesthetized mice. To resolve heartbeat- and respiration-dependent flow dynamics, we simultaneously recorded the electrocardiogram and respiratory waveform. We found that centerline RBC speed decreased with decreasing vessel diameter in arterioles, slowed further through the capillary bed, and then increased with increasing vessel diameter in venules. RBC flow was pulsatile in nearly all cortical vessels, including capillaries and venules. Heartbeat-induced speed modulation decreased through the vascular network, while the delay between heartbeat and the time of maximum speed increased. Capillary tube hematocrit was 0.21 and did not vary with centerline RBC speed or topological position. Spatial RBC flow profiles in surface vessels were blunted compared with a parabola and could be measured at vascular junctions. Finally, we observed a transient decrease in RBC speed in surface vessels before inspiration. In conclusion, we developed an approach to study detailed characteristics of RBC flow in the three-dimensional cortical vasculature, including quantification of fluctuations in centerline RBC speed due to cardiac and respiratory rhythms and flow profile measurements. These methods and the quantitative data on basal cerebral hemodynamics open the door to studies of the normal and diseased-state cerebral microcirculation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kleinfeld, D., Mitra, P. P., Helmchen, F., & Denk, W. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.26.15741 · Cited by 832
Schaffer, C. B., Friedman, B., Nishimura, N., Schroeder, L. F., Tsai, P. S., Ebner, F. F., Lyden, P. D., & Kleinfeld, D. (2006) · PLoS Biology · doi:10.1371/journal.pbio.0040022 · Cited by 400
Self-citationNishimura, N., Schaffer, C. B., Friedman, B., Tsai, P. S., Lyden, P. D., & Kleinfeld, D. (2006) · Nature Methods · doi:10.1038/nmeth844 · Cited by 308
Self-citationNguyen, J., Nishimura, N., Fetcho, R. N., Iadecola, C., & Schaffer, C. B. (2011) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2011.95 · Cited by 95
Self-citation
Cited by
Flow of cerebrospinal fluid is driven by arterial pulsations and is reduced in hypertension.
Mestre, H., Tithof, J., Du, T., Song, W., Peng, W., Sweeney, A. M., Olveda, G., Thomas, J. H., Nedergaard, M., & Kelley, D. H. (2018) · Nature Communications · doi:10.1038/s41467-018-07318-3 · Cited by 1,110
Rasmussen, M. K., Mestre, H., & Nedergaard, M. (2022) · Physiological Reviews · doi:10.1152/physrev.00031.2020 · Cited by 597
Cruz Hernández, J. C., Bracko, O., Kersbergen, C. J., Muse, V., Haft-Javaherian, M., Berg, M., Park, L., Vinarcsik, L. K., Ivasyk, I., Rivera, D. A., et al. (2019) · Nature Neuroscience · doi:10.1038/s41593-018-0329-4 · Cited by 508
Self-citationThe glymphatic system: Current understanding and modeling
Bohr, T., Hjorth, P. G., Holst, S. C., Hrabětová, S., Kiviniemi, V., Lilius, T., Lundgaard, I., Mardal, K.-A., Martens, E. A., Mori, Y., et al. (2022) · iScience · doi:10.1016/j.isci.2022.104987 · Cited by 368
Linville, R. M., DeStefano, J. G., Sklar, M. B., Xu, Z., Farrell, A. M., Bogorad, M. I., Chu, C., Walczak, P., Cheng, L., Mahairaki, V., et al. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2018.10.023 · Cited by 199
Metadata
- Authors
- Santisakultarm, T. P., Cornelius, N. R., Nishimura, N., Schafer, A. I., Silver, R. T., Doerschuk, P. C., Olbricht, W. L., & Schaffer, C. B.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2012-04-01
- Volume
- 302
- Issue
- 7
- Pages
- H1367-H1377
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2049092760
- Cited by
- 161
- References
- 4
- FWCI
- 8.06
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vivo two-photon excited fluorescence microscopy reveals cardiac- and respiration-dependent pulsatile blood flow in cortical blood vessels in mice. https://app.cochat.ai/papers/10.1152/ajpheart.00417.2011
- The paper
- Santisakultarm, T. P., Cornelius, N. R., Nishimura, N., Schafer, A. I., Silver, R. T., Doerschuk, P. C., Olbricht, W. L., & Schaffer, C. B. (2012). In vivo two-photon excited fluorescence microscopy reveals cardiac- and respiration-dependent pulsatile blood flow in cortical blood vessels in mice. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.00417.2011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.