Local vascular responses affecting blood flow in postural tachycardia syndrome
Abstract
Postural tachycardia syndrome (POTS) is defined by orthostatic intolerance associated with abnormal upright tachycardia. Some patients have defective peripheral vasoconstriction and increased calf blood flow. Others have increased peripheral arterial resistance and decreased blood flow. In 14 POTS patients (13–19 yr) evenly subdivided among low-flow POTS (LFP) and high-flow POTS (HFP) we tested the hypothesis that myogenic, venoarteriolar, and reactive hyperemic responses are abnormal. We used venous occlusion plethysmography to measure calf venous pressure and blood flow in the supine position and when the calf was lowered by 40 cm to evoke myogenic and venoarteriolar responses and during venous hypertension by 40-mmHg occlusion to evoke the venoarteriolar response. We measured calf reactive hyperemia with plethysmography and cutaneous laser-Doppler flowmetry. Baseline blood flow in LFP was reduced compared with HFP and control subjects (0.8 ± 0.2 vs. 4.4 ± 0.5 and 2.7 ± 0.4 ml · min –1 · 100 ml –1 ) but increased during leg lowering (1.2 ± 0.5 ml · min –1 · 100 ml –1 ) while decreasing in the others. Baseline peripheral arterial resistance was increased in LFP and decreased in HFP compared with control subjects (39 ± 13 vs. 15 ± 3 and 22 ± 5 mmHg · ml –1 · 100 ml · min) but decreased to 29 ± 13 mmHg · ml –1 · 100 ml · min in LFP during venous hypertension. Resistance increased in the other groups. Maximum calf hyperemic flow and cutaneous flow were similar in all subjects. The duration of hyperemic blood flow was curtailed in LFP compared with either control or HFP subjects (plethysmographic time constant = 20 ± 2 vs. 29 ± 4 and 28 ± 4 s; cutaneous time constant = 60 ± 25 vs. 149 ± 53 s in controls). Local blood flow regulation in low-flow POTS is impaired.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Pediatric patients with POTS had excessive pooling of blood in the lower extremities, primarily due to arteriolar dysregulation rather than inappropriately increased venous capacitance.
“Stewart et al. (14-17) noted that pediatric patients with POTS had excessive pooling of blood in the lower extremities, primarily due to arteriolar dysregulation rather than inappropriately increased venous capacitance.”
From Postural orthostatic tachycardia syndrome: mechanisms and new therapies (2020) · cites this paper as [15]
The citation lists haven’t been fetched yet
References 48 · Cited by 71
- Authors
- Stewart, J. M., Medow, M. S., & Montgomery, L. D.
- Affiliations
- New York Medical College (US)
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2003-12
- Volume
- 285
- Issue
- 6
- Pages
- H2749-H2756
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2167939412
- Cited by
- 71
- References
- 48
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 1 · 2023: 1 · 2022: 1 · 2021: 2 · 2020: 3 · 2019: 4 · 2018: 2 · 2017: 2 · 2016: 4 · 2014: 4 · 2013: 4 · 2012: 3
- FWCI
- 4.73
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Journal of Physiology-Heart and Circulatory Physiology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Heart, Lung, and Blood Institute (R01HL066007, 1R01 HL66007)
- Topics
- Health Sciences › Medicine › Surgery › Cardiovascular Syncope and Autonomic Disorders
- Health Sciences › Medicine › Complementary and alternative medicine › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- postural orthostatic tachycardia syndrome, orthostatic intolerance, calf blood flow, peripheral arterial resistance, myogenic response, reactive hyperemia, local blood flow regulation, venous occlusion, skin blood flow
- MeSH terms
- Adolescent, Adult, Humans, Hyperemia, Hypertension, Hypotension, Orthostatic, Leg, Posture, Regional Blood Flow, Tachycardia, Vascular Resistance, Vasoconstriction, Veins, Laser-Doppler Flowmetry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review