Systemic venous circulation. Waves propagating on a windkessel: relation of arterial and venous windkessels to systemic vascular resistance
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Compared with arterial hemodynamics, there has been relatively little study of venous hemodynamics. We propose that the venous system behaves just like the arterial system: waves propagate on a time-varying reservoir, the windkessel, which functions as the reverse of the arterial windkessel. During later diastole, pressure increases exponentially to approach an asymptotic value as inflow continues in the absence of outflow. Our study in eight open-chest dogs showed that windkessel-related arterial resistance was ∼62% of total systemic vascular resistance, whereas windkessel-related venous resistance was only ∼7%. Total venous compliance was found to be 21 times larger than arterial compliance ( n = 3). Inferior vena caval compliance (0.32 ± 0.015 ml·mmHg−1·kg−1; mean ± SE) was ∼14 times the aortic compliance (0.023 ± 0.002 ml·mmHg−1·kg−1; n = 8). Despite greater venous compliance, the variation in venous windkessel volume (i.e., compliance × windkessel pulse pressure; 7.8 ± 1.1 ml) was only ∼32% of the variation in aortic windkessel volume (24.3 ± 2.9 ml) because of the larger arterial pressure variation. In addition, and contrary to previous understanding, waves generated by the right heart propagated upstream as far as the femoral vein, but excellent proportionality between the excess pressure and venous outflow suggests that no reflected waves returned to the right atrium. Thus the venous windkessel model not only successfully accounts for variations in the venous pressure and flow waveforms but also, in combination with the arterial windkessel, provides a coherent view of the systemic circulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McDonald's Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles
Vlachopoulos, C., O'Rourke, M., & Nichols, W. W. (2011) · doi:10.1201/b13568 · Cited by 1,613
Cited by
Westerhof, N., Lankhaar, J.-W., & Westerhof, B. E. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0359-2 · Cited by 1,181
An introduction to wave intensity analysis
Parker, K. H. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-009-0439-y · Cited by 309
Self-citationWave intensity analysis and the development of the reservoir–wave approach
Tyberg, J. V., Davies, J. E., Wang, Z., Whitelaw, W. A., Flewitt, J. A., Shrive, N. G., Francis, D. P., Hughes, A. D., Parker, K. H., & Wang, J.-J. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0430-z · Cited by 104
“The presence of an arterial and a venous reservoir with their associated reservoir and large-artery/large-vein resistances invited a reconsideration of systemic vascular resistance as a network of individual resistances arranged in series [22] (see Fig.”
BackgroundMethodInfluentialSelf-citationManisty, C. H., & Hughes, A. D. (2013) · British Journal of Clinical Pharmacology · doi:10.1111/j.1365-2125.2012.04342.x · Cited by 99
Metadata
- Authors
- Wang, J.-J., Flewitt, J. A., Shrive, N. G., Parker, K. H., & Tyberg, J. V.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2006-01
- Volume
- 290
- Issue
- 1
- Pages
- H154-H162
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2010102852
- Cited by
- 72
- References
- 1
- FWCI
- 1.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.