Maximum shortening velocity of lymphatic muscle approaches that of striated muscle
Open accessAbstract
Lymphatic muscle (LM) is widely considered to be a type of vascular smooth muscle, even though LM cells uniquely express contractile proteins from both smooth muscle and cardiac muscle. We tested the hypothesis that LM exhibits an unloaded maximum shortening velocity (Vmax) intermediate between that of smooth muscle and cardiac muscle. Single lymphatic vessels were dissected from the rat mesentery, mounted in a servo-controlled wire myograph, and subjected to isotonic quick release protocols during spontaneous or agonist-evoked contractions. After maximal activation, isotonic quick releases were performed at both the peak and plateau phases of contraction. Vmax was 0.48 ± 0.04 lengths (L)/s at the peak: 2.3 times higher than that of mesenteric arteries and 11.4 times higher than mesenteric veins. In cannulated, pressurized lymphatic vessels, shortening velocity was determined from the maximal rate of constriction [rate of change in internal diameter (-dD/dt)] during spontaneous contractions at optimal preload and minimal afterload; peak -dD/dt exceeded that obtained during any of the isotonic quick release protocols (2.14 ± 0.30 L/s). Peak -dD/dt declined with pressure elevation or activation using substance P. Thus, isotonic methods yielded Vmax values for LM in the mid to high end (0.48 L/s) of those the recorded for phasic smooth muscle (0.05-0.5 L/s), whereas isobaric measurements yielded values (>2.0 L/s) that overlapped the midrange of values for cardiac muscle (0.6-3.3…
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Lymphatic muscle is characterized by an unusually high unloaded shortening velocity, with values exceeding those of other types of SM and under some conditions approaching speeds recorded for cardiac muscle.
“Lymphatic muscle is characterized by an unusually high unloaded shortening velocity, with values exceeding those of other types of SM and which, under some conditions, approach speeds recorded for cardiac muscle (82).”
From Transport and Immune Functions of the Lymphatic System. (2025) · cites this paper as [82]
Cited by
Sorted by citations
Transport and Immune Functions of the Lymphatic System.
Davis, M. J., Zawieja, S. D., & King, P. D. (2025) · Annual Review of Physiology · doi:10.1146/annurev-physiol-022724-104908 · Cited by 42 · see citing works
Self-citation
- Authors
- Zhang, R., Taucer, A. I., Gashev, A. A., Muthuchamy, M., Zawieja, D. C., & Davis, M. J.
- Affiliations
- Department of Pathology, University of Texas Medical School, Houston, Texas;
- Texas A&M University (US)
- Texas A&M Health Science Center (US)
- University of Missouri (US)
- Corresponding author
- Davis, Michael J.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2013-11-15
- Volume
- 305
- Issue
- 10
- Pages
- H1494-H1507
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- PMC
- PMC3840257
- OpenAlex
- W2151432823
- Cited by
- 26
- References
- 0
- Citations by year
- 2025: 2 · 2024: 2 · 2023: 3 · 2022: 2 · 2021: 2 · 2020: 1 · 2019: 3 · 2018: 3 · 2017: 1 · 2016: 2 · 2015: 1 · 2014: 3 · 2013: 1
- FWCI
- 1.25
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- American Journal of Physiology-Heart and Circulatory Physiology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Heart, Lung, and Blood Institute (HL089784, R01HL080526, R01HL075199, R01HL096552, HL075199, R01HL089784)
- Topics
- Health Sciences › Medicine › Oncology › Lymphatic System and Diseases
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Function and Risk Factors
- Health Sciences › Medicine › Surgery › Lymphatic Disorders and Treatments
- Keywords
- maximum shortening velocity, vascular smooth muscle, lymphatic vessel contraction, substance P, mesenteric lymphatics
- MeSH terms
- Animals, Isometric Contraction, Isotonic Contraction, Kinetics, Male, Mesentery, Muscle, Smooth, Muscle, Smooth, Vascular, Myocardium, Pressure, Lymphatic Vessels, Rats, Muscle, Striated
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review