CoChat

A microfluidic wound-healing assay for quantifying endothelial cell migration

van der Meer, Andries D., Vermeul, Kim, Poot, André A., Feijen, Jan, Vermes, István · 2010 · American Journal of Physiology-Heart and Circulatory Physiology
Cited by 146

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Endothelial migration is an important process in the formation of blood vessels and the repair of damaged tissue. To study this process in the laboratory, versatile and reliable migration assays are essential. The purpose of this study was to investigate whether the microfluidic version of the conventional wound-healing assay is a useful research tool for vascular science. Endothelial cells were seeded in a 500-μm-wide microfluidic channel. After overnight incubation, cells had formed a viable and confluent monolayer. Then, a wound was generated in this monolayer by flushing the channel with three parallel fluid streams, of which the middle one contained the protease trypsin. By analyzing the closing of the wound over time, endothelial cell migration could be measured. Although the migration rate was two times lower in the microfluidic assay than in the conventional assay, an identical 1.5-times increase in migration rate was found in both assays when vascular endothelial growth factor (VEGF 165) was added. In the microfluidic wound-healing assay, a stable gradient of VEGF 165 could be generated at the wound edge. This led to a two-times increase in migration rate compared with the untreated control. Finally, when a shear stress of 1.3 Pa was applied to the wound, the migration rate increased 1.8 times. In conclusion, the microfluidic assay is a solid alternative for the conventional wound-healing assay when endothelial cell migration is measured. Moreover, it offers unique advantages, such as gradient generation and application of shear stress.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpheart.00933.2009

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 146

Metadata

Authors
van der Meer, A. D., Vermeul, K., Poot, A. A., Feijen, J., & Vermes, I.
Venue
American Journal of Physiology-Heart and Circulatory Physiology
Published
2010-02
Volume
298
Issue
2
Pages
H719-H725
ISSN
  • 0363-6135 (ISSN-L)
  • 1522-1539
OpenAlex
W2120585583
Cited by
146
References
2
FWCI
2.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A microfluidic wound-healing assay for quantifying endothelial cell migration. https://app.cochat.ai/papers/10.1152/ajpheart.00933.2009
The paper
van der Meer, A. D., Vermeul, K., Poot, A. A., Feijen, J., & Vermes, I. (2010). A microfluidic wound-healing assay for quantifying endothelial cell migration. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.00933.2009

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.