Correlation of repolarization of ventricular monophasic action potential with ECG in the murine heart
The DOI matches its Crossref record.
Abstract
Transgenic mice have become important experimental models in the investigation of mechanisms causing cardiac arrhythmias because of the ability to create strains with alterations in repolarizing membrane currents. It is important to relate alterations in membrane currents in cells to their phenotypic expression on the electrocardiogram (ECG). The murine ECG, however, has unusual characteristics that make interpretation of the phenotypic expression of changes in ventricular repolarization uncertain. The major deflection representing the QRS (referred to as “ a”) is often followed by a secondary slower deflection (“ b”) and sometimes a subtle third deflection (“ c”). To determine whether the second or third deflections or both represent ventricular repolarization, we recorded the ventricular monophasic action potential (MAP) in open-chest mice and correlated repolarization with the ECG. There was no significant correlation by linear regression, between action potential duration to 50% or 90% repolarization (APD 50 or APD 90), respectively, of the MAP and either the interval from onset of Q to onset of b (Qb interval) or onset of c (Qc interval). Administration of 4-aminopyridine (4-AP) significantly prolonged APD 50 and APD 90 and the Qb interval, indicating that this deflection on the ECG represents part of ventricular repolarization. After 4-AP, the c wave disappeared, also suggesting that it represents a component of ventricular repolarization. Although it appears that both the b and c waves that follow the Q wave on the ECG represent ventricular repolarization, neither correlates exactly with APD 90 of the MAP. Therefore, an accurate measurement of complete repolarization of the murine ventricle cannot be obtained from the surface ECG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Costantini, D. L., Arruda, E. P., Agarwal, P., Kim, K.-H., Zhu, Y., Zhu, W., Lebel, M., Cheng, C. W., Park, C. Y., Pierce, S. A., et al. (2005) · Cell · doi:10.1016/j.cell.2005.08.004 · Cited by 229
Plakophilin-2 Is Required for Transcription of Genes That Control Calcium Cycling and Cardiac Rhythm
Cerrone, M., Montnach, J., Lin, X., Zhao, Y.-T., Zhang, M., Agullo-Pascual, E., Leo-Macias, A., Alvarado, F. J., Dolgalev, I., Karathanos, T. V., et al. (2017) · Nature Communications · doi:10.1038/s41467-017-00127-0 · Cited by 210
Cardiac electrophysiology in mice: a matter of size
Kaese, S., & Verheule, S. (2012) · Frontiers in Physiology · doi:10.3389/fphys.2012.00345 · Cited by 196
“Very diverse physiological parameter such as basal metabolic rate, life span, left ventricular ejection time, and ECG time intervals (RR, PR, QRS, and QT) scale with body mass (BM) (West et al., 1997, 1999; Noujaim et al., 2004, 2007; Popovic et al., 2005).”
BackgroundInfluentialThe Utility of the Small Rodent Electrocardiogram in Toxicology
Farraj, A. K., Hazari, M. S., & Cascio, W. E. (2011) · Toxicological Sciences · doi:10.1093/toxsci/kfr021 · Cited by 104
Brisinda, D., Caristo, M. E., & Fenici, R. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01048.2005 · Cited by 23
Metadata
- Authors
- Danik, S., Cabo, C., Chiello, C., Kang, S., Wit, A. L., & Coromilas, J.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2002-07-01
- Volume
- 283
- Issue
- 1
- Pages
- H372-H381
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2138046319
- Cited by
- 87
- References
- 0
- FWCI
- 3.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Correlation of repolarization of ventricular monophasic action potential with ECG in the murine heart. https://app.cochat.ai/papers/10.1152/ajpheart.01091.2001
- The paper
- Danik, S., Cabo, C., Chiello, C., Kang, S., Wit, A. L., & Coromilas, J. (2002). Correlation of repolarization of ventricular monophasic action potential with ECG in the murine heart. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.01091.2001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.