Carbon monoxide exchanges between the human fetus and mother: a mathematical model
The DOI matches its Crossref record.
Abstract
A mathematical model was developed to calculate maternal and fetal carboxyhemoglobin concentrations, [HbCO], as functions of time during and after exposure of the mother to various inspired CO concentrations. Effects of variation in alveolar ventilation rates, pulmonary and placental fiffusing capacities, cardiac output, endogenous carbon monoxide production and other factors were studied. Following a change in the inspired CO concentration, fetal HbCO lags behind maternal HbCO by several hours. During CO uptake, fetal HbCO eventually overtakes maternal, and approaches an equilibrium value as much as 10% higher than the mother's. During CO washout the fetal levels again lag behind the mothers. Results indicate that treatment of pregnant women who have elevated HbCO levels with 100% oxygen reduces the time necessary to reduce the maternal HbCO level as expected, but that the rate of fetal CO elimination is not increased as much as that of the mother. Changes in maternal and fetal HbCO were also calculated for a representative exposure to changing inspired CO levels produced by fluctuating levels of air pollution. Finally, the effects of carboxyhemoglobin on fetal oxygenation were studied, including the effects of high altitude and exercise.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Perinatal complications associated with maternal tobacco use
Andres, R. L., & Day, M.-C. (2000) · Seminars in Neonatology · doi:10.1053/siny.2000.0025 · Cited by 524
The biological effects of carbon monoxide on the pregnant woman, fetus, and newborn infant
Longo, L. D. (1977) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(77)90824-9 · Cited by 485
Self-citationPope, D. P., Mishra, V., Thompson, L., Siddiqui, A. R., Rehfuess, E. A., Weber, M., & Bruce, N. G. (2010) · Epidemiologic Reviews · doi:10.1093/epirev/mxq005 · Cited by 388
“Furthermore, fetal elimination of carbon monoxide is slower than in the mother (36).”
BackgroundSiddika, N., Balogun, H. A., Amegah, A. K., & Jaakkola, J. J. K. (2016) · Occupational and Environmental Medicine · doi:10.1136/oemed-2015-103086 · Cited by 115
“38 There is also a signi fi cant dose-dependent relationship between CO and COHb, and a developing fetus can be deprived of adequate oxygenation due to high levels of COHb, which may even lead to fetal death.”
Background
Metadata
- Authors
- Hill, E. P., Hill, J. R., Power, G. G., & Longo, L. D.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1977-03-01
- Volume
- 232
- Issue
- 3
- Pages
- H311-H323
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2114269165
- Cited by
- 85
- References
- 0
- FWCI
- 0.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Carbon monoxide exchanges between the human fetus and mother: a mathematical model. https://app.cochat.ai/papers/10.1152/ajpheart.1977.232.3.h311
- The paper
- Hill, E. P., Hill, J. R., Power, G. G., & Longo, L. D. (1977). Carbon monoxide exchanges between the human fetus and mother: a mathematical model. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1977.232.3.h311
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.