The DOI matches its Crossref record.
Microvascular hematocrit and red cell flow in resting and contracting striated muscle
Abstract
Microvascular hematocrit and its possible relation to oxygen supply were systematically examined. We studied the red cell volume fraction (hematocrit) in arterial blood and in capillaries under a variety of circumstances. Control capillary hematocrit averaged 10.4 +/- 2.0% (SE) and arteriolar (14.2 micrometer ID) hematocrit averaged 13.9 +/- 1.2% in cremaster muscles of pentobarbital-anesthetized hamsters. Carotid artery hematocrit was 53.2 +/- 0.6%. The low microvessel hematocrit could not be entirely explained by a high red cell flux through arteriovenous channels other than capillaries (shunting). Hematocrit was not only low at rest, but varied with physiological stimuli. A 1-Hz muscle contraction increased capillary hematocrit to 18.5 +/- 2.4%, and maximal vasodilation induced a rise to 39.3 +/- 9.5%. The quantitative relations between capillary red cell flux, arterial hematocrit, and total blood flow could be explained by a two-element model of microvascular blood flow that incorporated a relatively slow-moving plasma layer (1.2 micrometer). Such a model would generate a low microvessel hematocrit and might reduce the diffusion capacity of individual capillaries, but would not reduce time-averaged red cell flux or alter steady-state vascular oxygen supply.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The endothelial glycocalyx: composition, functions, and visualization
Reitsma, S., Slaaf, D. W., Vink, H., van Zandvoort, M. A. M. J., & oude Egbrink, M. G. A. (2007) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-007-0212-8 · Cited by 1,980
The Structure and Function of the Endothelial Glycocalyx Layer
Weinbaum, S., Tarbell, J. M., & Damiano, E. R. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151959 · Cited by 1,198
Blood Rheology and Hemodynamics
(2003) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-2003-44551 · Cited by 1,006
Pries, A. R., Secomb, T. W., & Gaehtgens, P. (2000) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s004240000307 · Cited by 898
The glycocalyx: a novel diagnostic and therapeutic target in sepsis
Uchimido, R., Schmidt, E. P., & Shapiro, N. I. (2019) · Critical Care · doi:10.1186/s13054-018-2292-6 · Cited by 710
Metadata
- Authors
- Klitzman, B., & Duling, B. R.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1979-10-01
- Volume
- 237
- Issue
- 4
- Pages
- H481-H490
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W1599476364
- Cited by
- 352
- References
- 0
- FWCI
- 12.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microvascular hematocrit and red cell flow in resting and contracting striated muscle. https://app.cochat.ai/papers/10.1152/ajpheart.1979.237.4.h481
- The paper
- Klitzman, B., & Duling, B. R. (1979). Microvascular hematocrit and red cell flow in resting and contracting striated muscle. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1979.237.4.h481
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.