The DOI matches its Crossref record.
Preferential streaming of ductus venosus blood to the brain and heart in fetal lambs
Abstract
In 16 chronically prepared fetal lambs we compared the systemic distribution of ductus venosus blood flow with that of abdominal inferior vena caval blood by simultaneously injecting microspheres labeled with different radionuclides into an umbilical vein and into the abdominal inferior vena cava. A significantly greater proportion of ductus venosus blood flow than of abdominal inferior vena caval blood flow supplied the brain, heart, and upper body; this resulted from streaming of ductus venosus blood flow within the thoracic inferior vena cava with preferential direction of that blood flow through the foramen ovale. Blood flows to upper and lower body structures and placenta calculated from umbilical venous microsphere injections and reference arterial blood samples did not differ from those computed fromabdominal inferior vena caval injections and reference samples. Thus, despite streamline blood flow within the fetal thoracic inferior vena cava, organ blood flows can be accurately measured with either an umbilical venous or an abdominal inferior vena caval injection of microspheres when either is combined with the appropriate reference arterial blood samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Limperopoulos, C., Tworetzky, W., McElhinney, D. B., Newburger, J. W., Brown, D. W., Robertson, R. L., Guizard, N., McGrath, E., Geva, J., Annese, D., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.865568 · Cited by 663
Distribution and regulation of blood flow in the fetal and neonatal lamb.
Rudolph, A. M. (1985) · Circulation Research · doi:10.1161/01.res.57.6.811 · Cited by 464
Self-citationHecher, K., Campbell, S., Doyle, P., Harrington, K., & Nicolaides, K. (1995) · Circulation · doi:10.1161/01.cir.91.1.129 · Cited by 444
An extra-uterine system to physiologically support the extreme premature lamb
Partridge, E. A., Davey, M. G., Hornick, M. A., McGovern, P. E., Mejaddam, A. Y., Vrecenak, J. D., Mesas-Burgos, C., Olive, A., Caskey, R. C., Weiland, T. R., et al. (2017) · Nature Communications · doi:10.1038/ncomms15112 · Cited by 430
Blood flow and the degree of shunting through the ductus venosus in the human fetus
Kiserud, T., Rasmussen, S., & Skulstad, S. (2000) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(00)70504-7 · Cited by 307
Metadata
- Authors
- Edelstone, D. I., & Rudolph, A. M.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1979-12-01
- Volume
- 237
- Issue
- 6
- Pages
- H724-H729
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2241179289
- Cited by
- 189
- References
- 0
- FWCI
- 1.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Preferential streaming of ductus venosus blood to the brain and heart in fetal lambs. https://app.cochat.ai/papers/10.1152/ajpheart.1979.237.6.h724
- The paper
- Edelstone, D. I., & Rudolph, A. M. (1979). Preferential streaming of ductus venosus blood to the brain and heart in fetal lambs. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1979.237.6.h724
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.