Regional blood flow measurement with pulsed Doppler flowmeter in conscious rat
Abstract
Development of techniques for the continuous measurement of regional blood flow and vascular resistance in intact small animals has been impeded primarily by the bulkiness of flow probes. The availability of an ultrasonic pulsed Doppler flowmeter system enabled us to construct miniaturized probes using 1-mm-diameter piezoelectric crystals that emit a 20-mHz signal and receive the reflected sound waves from passing blood cells. The finished flow probe is approximately 2.5-4 mm long and 2 mm in cross-sectional diameter with lumen diameters appropriate for the rat, ranging from 0.7 to 1.2 mm. This report describes the materials and methods involved in constructing and implanting the probes in rats to monitor renal, mesenteric, and hindquarter blood flow velocity. The accuracy of the pulsed Doppler method in detecting changes in regional blood flow and vascular resistance was established by the demonstration of a highly significant correlation between velocity recorded from the Doppler unit and volume flow recorded simultaneously. These data indicate that the ultrasonic pulsed Doppler flowmeter provides the opportunity to measure changes in regional blood flow and vascular resistance in a conscious freely moving rat.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An ultrasonic pulsed Doppler system for measuring blood flow in small vessels.
Hartley, C. J., & Cole, J. S. (1974) · Journal of Applied Physiology · doi:10.1152/jappl.1974.37.4.626 · Cited by 354
Simultaneous comparison and calibration of the Doppler and electromagnetic flowmeters
Vatner, S. F., Franklin, D., & VanCitters, R. L. (1970) · Journal of Applied Physiology · doi:10.1152/jappl.1970.29.6.907 · Cited by 123
Touw, K. B., Haywood, J. R., Shaffer, R. A., & Brody, M. J. (1980) · Hypertension · doi:10.1161/01.hyp.2.4.408 · Cited by 76
Self-citation
Cited by
Control of regional blood flow by endothelium-derived nitric oxide.
Gardiner, S. M., Compton, A. M., Bennett, T., Palmer, R. M., & Moncada, S. (1990) · Hypertension · doi:10.1161/01.hyp.15.5.486 · Cited by 436
Rat model of arterial thrombosis induced by ferric chloride
Kurz, K. D., Main, B. W., & Sandusky, G. E. (1990) · Thrombosis Research · doi:10.1016/0049-3848(90)90106-m · Cited by 431
Thomas, G. D., Sander, M., Lau, K. S., Huang, P. L., Stull, J. T., & Victor, R. G. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.25.15090 · Cited by 376
Role of nitric oxide in renal medullary oxygenation. Studies in isolated and intact rat kidneys.
Brezis, M., Heyman, S. N., Dinour, D., Epstein, F. H., & Rosen, S. (1991) · Journal of Clinical Investigation · doi:10.1172/jci115316 · Cited by 281
Gardiner, S. M., Compton, A. M., Kemp, P. A., & Bennett, T. (1990) · British Journal of Pharmacology · doi:10.1111/j.1476-5381.1990.tb14131.x · Cited by 263
Metadata
- Authors
- Haywood, J. R., Shaffer, R. A., Fastenow, C., Fink, G. D., & Brody, M. J.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1981-08-01
- Volume
- 241
- Issue
- 2
- Pages
- H273-H278
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2148172817
- Cited by
- 363
- References
- 3
- FWCI
- 5.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Regional blood flow measurement with pulsed Doppler flowmeter in conscious rat. https://app.cochat.ai/papers/10.1152/ajpheart.1981.241.2.h273
- The paper
- Haywood, J. R., Shaffer, R. A., Fastenow, C., Fink, G. D., & Brody, M. J. (1981). Regional blood flow measurement with pulsed Doppler flowmeter in conscious rat. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1981.241.2.h273
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).