Capillary network geometry and red cell distribution in hamster cremaster muscle
The DOI matches its Crossref record.
Abstract
Vascular geometry and red cell distribution were examined in 133 capillaries by means of intravital microscopy in the cremaster muscle of the pentobarbital-anesthetized hamster. Significant correlations (P less than 0.01) were found between diameter and flow, length and resistance, red cell transit time and flow, and red cell flux and hematocrit. Most unexpected was the lack of correlation (P greater than 0.2) between flow and resistance, length, or hematocrit. In addition, we analyzed the relation between blood flow and red cell flux at capillary bifurcations. The red blood cells had a slight (7%), but significant (P less than 0.025), tendency to enter the branch having either higher flow, red cell velocity, or pseudoshear rate (velocity/diameter). The net effect of the preferential red cell flow was to reduce mean capillary hematocrit from 13.7% prior to the bifurcation to 13.3% in the two branches. Finally, increasing the oxygen level of the superfusate above the muscle caused vasoconstriction and an increased heterogeneity of capillary red cell flux and hematocrit, decreasing the capacity for oxygen transport to the tissue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The endothelial glycocalyx: composition, functions, and visualization
Reitsma, S., Slaaf, D. W., Vink, H., van Zandvoort, M. A. M. J., & oude Egbrink, M. G. A. (2007) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-007-0212-8 · Cited by 1,980
Biophysical aspects of blood flow in the microvasculature
Pries, A. R., Secomb, T. W., & Gaehtgens, P. (1996) · Cardiovascular Research · doi:10.1016/s0008-6363(96)00065-x · Cited by 553
The sex difference in haemoglobin levels in adults—mechanisms, causes, and consequences
Murphy, W. G. (2014) · Blood Reviews · doi:10.1016/j.blre.2013.12.003 · Cited by 463
“This can be ascribed to modulation of the vessel diameter — microvascular vasodilation will raise the red cell content in the vessels through the Fåhraeus effect [46–49].”
BackgroundMicrovascular Rheology and Hemodynamics
LIPOWSKY, H. H. (2005) · Microcirculation · doi:10.1080/10739680590894966 · Cited by 414
Skeletal muscle capillary hemodynamics from rest to contractions: implications for oxygen transfer
Kindig, C. A., Richardson, T. E., & Poole, D. C. (2002) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01222.2001 · Cited by 200
“Specifically, greater within-microcirculatory unit Hctcap uniformity would be expected if capillary Hctcap were under arteriolar control (20, 27, 33).”
Background
Metadata
- Authors
- Klitzman, B., & Johnson, P. C.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1982-02-01
- Volume
- 242
- Issue
- 2
- Pages
- H211-H219
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2427703062
- Cited by
- 129
- References
- 0
- FWCI
- 4.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Capillary network geometry and red cell distribution in hamster cremaster muscle. https://app.cochat.ai/papers/10.1152/ajpheart.1982.242.2.h211
- The paper
- Klitzman, B., & Johnson, P. C. (1982). Capillary network geometry and red cell distribution in hamster cremaster muscle. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1982.242.2.h211
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.