Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 333

The DOI matches its Crossref record.

Muscular blood flow distribution patterns as a function of running speed in rats

Laughlin, M. H., Armstrong, R. B.·1982·American Journal of Physiology-Heart and Circulatory Physiology

Abstract

Muscle blood flow (BF) was measured using the radiolabeled microsphere technique within and among nine major muscles of rats before exercise and during treadmill walking or running at speeds of 15, 30, 45, 60, and 75 m/min. Measurements were made during exercise after 1 min of steady walking or running. Male Sprague-Dawley rats were chronically instrumented with 2 Silastic catheters, one in the ascending aorta via the right carotid artery for microsphere infusion and one in the left renal artery for arterial reference blood sample withdrawal. The preexercise results demonstrated that 1) BF to deep slow-twitch muscles was three to four times that to peripheral fast muscles (e.g., soleus and gastrocnemius BFs were 138 and 33 ml . min-1 . 100 g-1, respectively); 2) BFs to red portions within mixed muscles were three to four times those to white portions (e.g, red and white gastrocnemius BFs were 54 and 18 ml . min-1 . 100 g-1, respectively; and 3) there was a direct relationship (P less than 0.05) between BFs to muscles and their slow-twitch oxidative fiber populations. The results obtained during exercise demonstrated that 1) at the slowest speed studied (15 m/min) BFs to the red portions of muscles increased, whereas BFs to the white portions of the same muscles decreased; 2) BFs to all muscles (except soleus) were increased during running at 75 m/min when there was a range of flows of 30 ml . 100 g-1 . min-1 (white gastrocnemius) to 321 (vastus intermedius), 3) at all running speeds the increases in BF to muscles were directly related to the fast-twitch, high-oxidative fiber populations of the muscles; and 4) BFs to visceral tissues and fat were decreased during exercise.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpheart.1982.243.2.h296

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 333

Metadata

Authors
Laughlin, M. H., & Armstrong, R. B.
Venue
American Journal of Physiology-Heart and Circulatory Physiology
Published
1982-08-01
Volume
243
Issue
2
Pages
H296-H306
ISSN
  • 0363-6135 (ISSN-L)
  • 1522-1539
OpenAlex
W2171980151
Cited by
333
References
0
FWCI
14.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Muscular blood flow distribution patterns as a function of running speed in rats. https://app.cochat.ai/papers/10.1152/ajpheart.1982.243.2.h296
The paper
Laughlin, M. H., & Armstrong, R. B. (1982). Muscular blood flow distribution patterns as a function of running speed in rats. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1982.243.2.h296

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.