O2 gradients from sarcolemma to cell interior in red muscle at maximal VO2
The DOI matches its Crossref record.
Abstract
The intracellular distribution of O2 in cross sections of dog gracilis muscles was determined by myoglobin (Mb) cryospectrophotometry. The volume sampled by the photometer was approximately 30 micron3 and contained 1-2 mitochondria. Measurements could be made to within 3 micron of capillaries without interference from hemoglobin. Mb saturation was uniform at all loci examined when respiration was blocked with cyanide. During twitch contraction at maximum O2 consumption, saturations within a cell cross section varied by up to 20%. The corresponding difference in partial pressure of O2 (PO2) was 1.5 Torr. Circumferential O2 gradients parallel to and 5 micron from the sarcolemma were greatest near capillaries. They did not exceed 0.1 Torr/micron and were dissipated within 25 micron of the sarcolemma. Gradients perpendicular to the sarcolemma were less than 0.02 Torr/micron. Saturation was not significantly correlated with cell diameter. Minimum PO2 was seldom located at the center of the cell cross section. Differences in saturation between contiguous cells often exceeded 10%. The distribution of O2 within cells appeared to reflect both an intercellular O2 flux and and an O2 flux from adjacent capillaries. Data agree qualitatively and quantitatively with mathematical models that take account of the particulate nature of blood and facilitated diffusion by Mb.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wittenberg, J. B., & Wittenberg, B. A. (2003) · Journal of Experimental Biology · doi:10.1242/jeb.00243 · Cited by 550
Oxygen Gradients in the Microcirculation
TSAI, A. G., JOHNSON, P. C., & INTAGLIETTA, M. (2003) · Physiological Reviews · doi:10.1152/physrev.00034.2002 · Cited by 450
Defining hypoxia: a systems view of VO2, glycolysis, energetics, and intracellular PO2
Connett, R. J., Honig, C. R., Gayeski, T. E., & Brooks, G. A. (1990) · Journal of Applied Physiology · doi:10.1152/jappl.1990.68.3.833 · Cited by 389
Self-citationControl of mitochondrial and cellular respiration by oxygen
Gnaiger, E., Steinlechner-Maran, R., Méndez, G., Eberl, T., & Margreiter, R. (1995) · Journal of Bioenergetics and Biomembranes · doi:10.1007/bf02111656 · Cited by 315
Muscle mitochondrial capacity exceeds maximal oxygen delivery in humans
Boushel, R., Gnaiger, E., Calbet, J. A. L., Gonzalez-Alonso, J., Wright-Paradis, C., Sondergaard, H., Ara, I., Helge, J. W., & Saltin, B. (2011) · Mitochondrion · doi:10.1016/j.mito.2010.12.006 · Cited by 150
Metadata
- Authors
- Gayeski, T. E., & Honig, C. R.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1986-10-01
- Volume
- 251
- Issue
- 4
- Pages
- H789-H799
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2263602363
- Cited by
- 141
- References
- 0
- FWCI
- 14.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: O2 gradients from sarcolemma to cell interior in red muscle at maximal VO2. https://app.cochat.ai/papers/10.1152/ajpheart.1986.251.4.h789
- The paper
- Gayeski, T. E., & Honig, C. R. (1986). O2 gradients from sarcolemma to cell interior in red muscle at maximal VO2. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1986.251.4.h789
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.