The DOI matches its Crossref record.
Quantitative fluorescence microscopy on single capillaries: alpha-lactalbumin transport
Abstract
We have extended the use of a microscope densitometric technique [Am. J. Physiol. 245 (Heart Circ. Physiol. 14): H495-H505, 1983] to measure the solute permeability coefficients (Pa) of fluorescently labeled solutes in single perfused capillaries of frog mesentery. The method enables the transcapillary flux of solutes larger than 10,000 mol wt to be measured under conditions where the forces that determine both solute and water flows across the capillary wall are known. The Pa for alpha-lactalbumin (mol wt 14,176, Stokes radius 2.02 nm) increased from a mean value of 2.1 X 10(-6) cm/s when capillary pressure was 3.0 cmH2O (no net filtration) to greater than 4.0 X 10(-6) cm/s when capillary pressure was 15 cmH2O. Taking a value of 0.35 for the solvent drag reflection coefficient for alpha-lactalbumin, we conclude that the increased solute flux represents solvent drag through a water pathway with a hydraulic conductivity of 3.6 X 10(-7) cm X s-1 X cmH2O-1. Our data conforms to the hypothesis that alpha-lactalbumin is transported across the capillary wall by restricted diffusion and solvent drag in a pathway that carries 90% of the transcapillary water flow (the principle water pathway). In vitro and in vivo calibration experiments have been carried out to test the assumption that the measured fluorescent light intensity is proportional to the number of fluorescent molecules in the measuring window of the photometer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Formation of perfused, functional microvascular tubes in vitro
Chrobak, K. M., Potter, D. R., & Tien, J. (2006) · Microvascular Research · doi:10.1016/j.mvr.2006.02.005 · Cited by 553
Shirure, V. S., Bi, Y., Curtis, M. B., Lezia, A., Goedegebuure, M. M., Goedegebuure, S. P., Aft, R., Fields, R. C., & George, S. C. (2018) · Lab on a Chip · doi:10.1039/c8lc00596f · Cited by 316
Silk fibroin microtubes for blood vessel engineering
Lovett, M., Cannizzaro, C., Daheron, L., Messmer, B., Vunjak-Novakovic, G., & Kaplan, D. L. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.08.008 · Cited by 273
Kutuzov, N., Flyvbjerg, H., & Lauritzen, M. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1802155115 · Cited by 250
Linville, R. M., DeStefano, J. G., Sklar, M. B., Xu, Z., Farrell, A. M., Bogorad, M. I., Chu, C., Walczak, P., Cheng, L., Mahairaki, V., et al. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2018.10.023 · Cited by 199
Metadata
- Authors
- Huxley, V. H., Curry, F. E., & Adamson, R. H.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1987-01-01
- Volume
- 252
- Issue
- 1
- Pages
- H188-H197
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W150340686
- Cited by
- 161
- References
- 0
- FWCI
- 0.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative fluorescence microscopy on single capillaries: alpha-lactalbumin transport. https://app.cochat.ai/papers/10.1152/ajpheart.1987.252.1.h188
- The paper
- Huxley, V. H., Curry, F. E., & Adamson, R. H. (1987). Quantitative fluorescence microscopy on single capillaries: alpha-lactalbumin transport. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1987.252.1.h188
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.