The DOI matches its Crossref record.
Blood viscosity in small tubes: effect of shear rate, aggregation, and sedimentation
Abstract
Apparent viscosity was determined in vertical glass tubes (ID 30.2-132.3 microns) with suspensions of human red cells in A) serum, B) saline containing 0.5 g/100 ml albumin, C) plasma, and D) plasma containing Dextran 250 at a feed hematocrit of 0.45. Pressure-flow relationships were obtained in a range of pseudo-shear rates (mu) between 0.15 and 250 s-1. Relative viscosities in the nonaggregating suspensions (A and B) were found to increase monotonically with decreasing mu. The Fahraeus-Lindqvist effect was present in the entire range of mu. In the two aggregating suspensions (C and D), viscosities increased initially in larger but not small tubes with declining mu and fell in all tubes at some characteristic mu (usually below 10 s-1). Viscosity reduction was greater in the larger tubes and in suspensions with greater aggregation tendency. With suspension D, the Fahraeus-Lindqvist effect was eliminated in the lowermost shear-rate range. The cell-free marginal zone increased in width (to a maximum of approximately 40% of tube radius) as viscosity declined. Measurements of viscosity and cell-free marginal zone were also performed with suspension C in tubes mounted in horizontal position. In contrast to vertical tubes, a monotonic increase in viscosity was found with decreasing mu, associated with cell sedimentation and development of a cell-free layer only in the upper portion of the tubes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Blood Rheology and Hemodynamics
(2003) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-2003-44551 · Cited by 1,006
MICROCIRCULATION AND HEMORHEOLOGY
Popel, A. S., & Johnson, P. C. (2005) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.37.042604.133933 · Cited by 831
Self-citationMicrovascular Rheology and Hemodynamics
LIPOWSKY, H. H. (2005) · Microcirculation · doi:10.1080/10739680590894966 · Cited by 414
Biomedical microfluidic devices by using low-cost fabrication techniques: A review
Faustino, V., Catarino, S. O., Lima, R., & Minas, G. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.11.031 · Cited by 338
Tsai, M., Kita, A., Leach, J., Rounsevell, R., Huang, J. N., Moake, J., Ware, R. E., Fletcher, D. A., & Lam, W. A. (2012) · Journal of Clinical Investigation · doi:10.1172/jci58753 · Cited by 297
Metadata
- Authors
- Reinke, W., Gaehtgens, P., & Johnson, P. C.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1987-09-01
- Volume
- 253
- Issue
- 3
- Pages
- H540-H547
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2405928241
- Cited by
- 171
- References
- 0
- FWCI
- 0.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Blood viscosity in small tubes: effect of shear rate, aggregation, and sedimentation. https://app.cochat.ai/papers/10.1152/ajpheart.1987.253.3.h540
- The paper
- Reinke, W., Gaehtgens, P., & Johnson, P. C. (1987). Blood viscosity in small tubes: effect of shear rate, aggregation, and sedimentation. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1987.253.3.h540
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.