Arteriolar oxygen reactivity: where is the sensor?
The DOI matches its Crossref record.
Abstract
The hypothesis that arterioles are intrinsically sensitive to oxygen was tested by comparing arteriolar diameter responses with local and global PO2 changes in superfused hamster cheek pouch preparations. Local PO2 changes were produced by microapplication of fluid onto the surface of occluded or unoccluded aparenchymal arterioles or by cannulation and perfusion of arterioles in situ. Global changes refer to PO2 changes in the superfusate flowing over the entire preparation. Local, effective PO2 changes had no significant effect on arteriolar diameters. In contrast, global PO2 changes produced significant, reproducible changes in diameter. These observations do not support the hypothesis that arterioles are intrinsically oxygen sensitive, unless the oxygen-sensitive sites are distributed sparsely along the arteriolar tree. The data are consistent with oxygen sensors located either in vessels downstream from 15-micron arterioles (in terminal arterioles, capillaries, or venules) or in the parenchyma. The data also suggest that these sensors detect changes in PO2 and then initiate responses that can be conducted along the vasculature to an arteriole distant from the sensor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Regulation of Blood Flow in the Microcirculation
SEGAL, S. S. (2005) · Microcirculation · doi:10.1080/10739680590895028 · Cited by 540
Singel, D. J., & Stamler, J. S. (2005) · Annual Review of Physiology · doi:10.1146/annurev.physiol.67.060603.090918 · Cited by 481
González-Alonso, J., Olsen, D. B., & Saltin, B. (2002) · Circulation Research · doi:10.1161/01.res.0000044939.73286.e2 · Cited by 331
Erythrocytes: Oxygen Sensors and Modulators of Vascular Tone
Ellsworth, M. L., Ellis, C. G., Goldman, D., Stephenson, A. H., Dietrich, H. H., & Sprague, R. S. (2009) · Physiology · doi:10.1152/physiol.00038.2008 · Cited by 321
Regulation of Coronary Blood Flow
Goodwill, A. G., Dick, G. M., Kiel, A. M., & Tune, J. D. (2017) · Comprehensive Physiology · doi:10.1002/cphy.c160016 · Cited by 297
Metadata
- Authors
- Jackson, W. F.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1987-11-01
- Volume
- 253
- Issue
- 5
- Pages
- H1120-H1126
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2228034435
- Cited by
- 93
- References
- 0
- FWCI
- 0.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Arteriolar oxygen reactivity: where is the sensor? https://app.cochat.ai/papers/10.1152/ajpheart.1987.253.5.h1120
- The paper
- Jackson, W. F. (1987). Arteriolar oxygen reactivity: where is the sensor? American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1987.253.5.h1120
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.