Intracellular PO2 in long axis of individual fibers in working dog gracilis muscle
The DOI matches its Crossref record.
Abstract
Dog gracilis muscles were frozen in situ during twitch contraction at 25–100% of aerobic capacity. O2 saturation of myoglobin (Mb) was determined from spectrophotometric measurements along individual fibers. Intracellular PO2 was calculated from the oxymyoglobin dissociation curve. At all work rates, long lengths of fibers were found in which saturation and PO2 were within the 4% error of measurement. During work at approximately 25% of aerobic capacity, Mb functioned at high saturation on the shallow slope of its dissociation curve. Consequently PO2 was poorly buffered. Although the range of saturation was small, PO2 varied up to 15 Torr along a fiber, and gradients up to 0.3 Torr/micron were observed. In contrast, at high O2 consumption (VO2), Mb functioned on the steep slope of its dissociation curve. Therefore gradients in intracellular PO2 along the axis of a myocyte were small (less than 0.05 Torr/micron) despite large gradients in Mb saturation (up to 0.5%/micron). Changes in intracellular PO2 over hundreds of microns did not reflect the large drop in intracapillary PO2 between arterioles and venules. Because intracellular PO2 is low and relatively uniform in the long axis of a fiber, the driving force for release of O2 from blood is dominated by intravascular PO2 in working red muscle.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Myoglobin O2 desaturation during exercise. Evidence of limited O2 transport.
Richardson, R. S., Noyszewski, E. A., Kendrick, K. F., Leigh, J. S., & Wagner, P. D. (1995) · Journal of Clinical Investigation · doi:10.1172/jci118237 · Cited by 647
Wittenberg, J. B., & Wittenberg, B. A. (2003) · Journal of Experimental Biology · doi:10.1242/jeb.00243 · Cited by 550
“Likewise, myoglobin saturation in red skeletal muscle, working near maximum sustainable oxygen consumption, is controlled near 50% saturation (Gayeski and Honig, 1986, 1988).”
BackgroundDeterminants of maximal oxygen transport and utilization
Wagner, P. D. (1996) · Annual Review of Physiology · doi:10.1146/annurev.ph.58.030196.000321 · Cited by 421
Defining hypoxia: a systems view of VO2, glycolysis, energetics, and intracellular PO2
Connett, R. J., Honig, C. R., Gayeski, T. E., & Brooks, G. A. (1990) · Journal of Applied Physiology · doi:10.1152/jappl.1990.68.3.833 · Cited by 389
Self-citationEvidence of O2 supply-dependentV˙o 2 max in the exercise-trained human quadriceps
Richardson, R. S., Grassi, B., Gavin, T. P., Haseler, L. J., Tagore, K., Roca, J., & Wagner, P. D. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.86.3.1048 · Cited by 234
“have provided evidence supporting the concept that O2 supply, rather than biochemical limitation (8, 30), sets V̇O2max.”
Background
Metadata
- Authors
- Gayeski, T. E., & Honig, C. R.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1988-06-01
- Volume
- 254
- Issue
- 6
- Pages
- H1179-H1186
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2199345539
- Cited by
- 84
- References
- 0
- FWCI
- 1.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intracellular PO2 in long axis of individual fibers in working dog gracilis muscle. https://app.cochat.ai/papers/10.1152/ajpheart.1988.254.6.h1179
- The paper
- Gayeski, T. E., & Honig, C. R. (1988). Intracellular PO2 in long axis of individual fibers in working dog gracilis muscle. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1988.254.6.h1179
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.