Cited by 3Sepsis Diagnosis and TreatmentRespiratory Support and MechanismsInflammation biomarkers and pathways

The DOI matches its Crossref record; its reference list is not available.

Pulmonary and peripheral lymph protein clearance during bacteremia after surgery

Charash, W. E., Saba, T. M., Lewis, E. P., Lewis, M. A.·1988·American Journal of Physiology-Heart and Circulatory Physiology

Abstract

An increase in pulmonary transvascular protein clearance is seen in sheep following postoperative bacteremia. We evaluated whether this increased protein clearance is specific for the lung by comparing in sheep the effect of postoperative bacteremia on both pulmonary and prefemoral lymph protein clearance. Fibronectin, implicated as a factor influencing vascular permeability, was also measured. After intravenous infusion of a sublethal dose of 5 x 10(8) live Pseudomonas aeruginosa (n = 10), pulmonary lymph flow (QL) increased 146% (P less than 0.01), and the lung lymph-to-plasma (L/P) total protein concentration ratio increased 21% (P less than 0.05). This resulted in a 208% elevation (P less than 0.01) in lung protein clearance (LPC = QL x L/P). In contrast, peripheral lymph flow and peripheral protein clearance were not altered. After intravenous infusion of a lethal dose of 5 x 10(9) live Pseudomonas (n = 7), QL rose 243-348% (P less than 0.025), whereas the lung L/P remained at base line, resulting in a 240-358% increase in LPC (P less than 0.025). Again, peripheral lymph flow and protein clearance did not increase. Plasma fibronectin declined slightly after low-dose bacterial challenge but decreased (P less than 0.001) 40% by 4-5 h after high-dose bacterial challenge. After both low- and high-dose bacterial challenge, fibronectin in pulmonary lymph increased (P less than 0.05) relative to total protein. In contrast, no change in peripheral lymph fibronectin was seen. Thu…

Overview

Integrity signals

Registry

Crossref · 10.1152/ajpheart.1988.255.6.h1421

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

No citation lists for this paper

No citation lists for this paper yet — checked again daily.

Cited by 3

Metadata

Authors
Charash, W. E., Saba, T. M., Lewis, E. P., & Lewis, M. A.
Affiliations
Albany Medical College (US)
Venue
American Journal of Physiology-Heart and Circulatory Physiology
Published
1988-12-01
Volume
255
Issue
6
Pages
H1421-H1428
ISSN
  • 0363-6135 (ISSN-L)
  • 1522-1539
OpenAlex
W2216685445
Cited by
3
References
0
Citations by year
2021: 1 · 2018: 1
FWCI
0.35
Type
journal article
Language
en
Open access
closed
Locations
  • American Journal of Physiology-Heart and Circulatory Physiology (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Institute of General Medical Sciences (GM-21447, T32GM007033, T32GM07033)
Topics
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Sepsis Diagnosis and Treatment
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
  • Life Sciences › Immunology and Microbiology › Immunology › Inflammation biomarkers and pathways
Keywords
postoperative bacteremia, lung lymph flow, fibronectin, Pseudomonas aeruginosa, vascular permeability, sheep model
MeSH terms
Animals, Blood Pressure, Blood Proteins, Cardiac Output, Fistula, Lung, Lymph, Male, Postoperative Complications, Proteins, Pseudomonas Infections, Reference Values, Sheep, Sepsis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pulmonary and peripheral lymph protein clearance during bacteremia after surgery. https://app.cochat.ai/papers/10.1152/ajpheart.1988.255.6.h1421
The paper
Charash, W. E., Saba, T. M., Lewis, E. P., & Lewis, M. A. (1988). Pulmonary and peripheral lymph protein clearance during bacteremia after surgery. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1988.255.6.h1421