Oxygen exchange in the microcirculation of hamster retractor muscle
The DOI matches its Crossref record.
Abstract
We determined percent hemoglobin oxygen saturation (SO2) in arterioles and venules of the hamster retractor muscle at rest. We found that SO2 decreased from 69.9 +/- 1.4% (SE) in large input arterioles (first order, 1A, ID = 60 +/- 3 micron) to flow-weighted values of 56.7% in small arterioles (4A, ID = 20 +/- 1 micron), 51.3% in small venules (4V, ID = 28 +/- 1 micron), and to 50.6 +/- 1.0% in large venules (1V, ID = 147 +/- 13 micron). Thus approximately two-thirds of the net decline in SO2 for this tissue occurred by diffusion of oxygen from arterioles, whereas only about one-third occurred by diffusion from capillaries. Furthermore, no net shunting of oxygen from the arterioles to the venules was detected as evidenced by the absence of any significant change in venular SO2. By determining the SO2 at upstream and downstream ends of arterioles in four consecutive branching orders (1A-4A), we found that the decrease in SO2 per unit length (delta SO2/L) increased approximately 20-fold from 1A to 4A. This increase in delta SO2/L was directly proportional to estimated luminal minus tissue oxygen tension and inversely proportional to red blood cell flow.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The biological lifetime of nitric oxide: Implications for the perivascular dynamics of NO and O 2
Thomas, D. D., Liu, X., Kantrow, S. P., & Lancaster, J. R. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.98.1.355 · Cited by 760
Oxygen Gradients in the Microcirculation
TSAI, A. G., JOHNSON, P. C., & INTAGLIETTA, M. (2003) · Physiological Reviews · doi:10.1152/physrev.00034.2002 · Cited by 450
Erythrocytes: Oxygen Sensors and Modulators of Vascular Tone
Ellsworth, M. L., Ellis, C. G., Goldman, D., Stephenson, A. H., Dietrich, H. H., & Sprague, R. S. (2009) · Physiology · doi:10.1152/physiol.00038.2008 · Cited by 321
Eigenspectra optoacoustic tomography achieves quantitative blood oxygenation imaging deep in tissues
Tzoumas, S., Nunes, A., Olefir, I., Stangl, S., Symvoulidis, P., Glasl, S., Bayer, C., Multhoff, G., & Ntziachristos, V. (2016) · Nature Communications · doi:10.1038/ncomms12121 · Cited by 248
Regulation of Tissue Oxygenation
Pittman, R. N. (2011) · Colloquium Series on Integrated Systems Physiology: From Molecule to Function · doi:10.4199/c00029ed1v01y201103isp017 · Cited by 246
Self-citation
Metadata
- Authors
- Swain, D. P., & Pittman, R. N.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1989-01-01
- Volume
- 256
- Issue
- 1
- Pages
- H247-H255
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2271047860
- Cited by
- 90
- References
- 0
- FWCI
- 1.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Oxygen exchange in the microcirculation of hamster retractor muscle. https://app.cochat.ai/papers/10.1152/ajpheart.1989.256.1.h247
- The paper
- Swain, D. P., & Pittman, R. N. (1989). Oxygen exchange in the microcirculation of hamster retractor muscle. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1989.256.1.h247
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.