Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 215

The DOI matches its Crossref record.

Low-frequency oscillations in arterial pressure and heart rate: a simple computer model

Madwed, J. B., Albrecht, P., Mark, R. G., Cohen, R. J.·1989·American Journal of Physiology-Heart and Circulatory Physiology

Abstract

We have previously reported that low-frequency oscillations in arterial blood pressure (ABP) and heart rate (HR) occur when conscious dogs experience severe blood loss. These low-frequency oscillations are generated by enhancement of the sympathetic nervous system and inhibition of the parasympathetic nervous system. We have developed a simple computer model to elucidate those properties critical to the generation of these oscillations. Our model incorporates several important features: 1) arterial baroreceptor feedback loops, which relate ABP to targeted HR and total peripheral resistance (TPR) values; 2) two effector outputs, HR and TPR, which are controlled by the outputs of vagal, beta-adrenergic, and alpha-adrenergic effector mechanisms; 3) a fixed beat-to-beat stroke volume; and 4) a wind-kessel model, which represents the peripheral circulation. Each effector mechanism is modeled as a low-pass filter in series with a delay. The vagal effector mechanism slows the HR after a 100-ms delay and reaches maximal HR at that time. The beta-adrenergic effector mechanism speeds HR after a 2.5-s delay and then increases to maximal HR 7.5 s later. The alpha-adrenergic effector mechanism begins vasoconstriction after a 5-s delay and then reaches maximal contraction 15 s later. Computer simulations of inhibition of the vagal effector mechanism and activation of the adrenergic effector mechanisms elicit low-frequency oscillations in ABP and HR. These oscillations are similar to those observed experimentally in the dog during hemorrhage. We conclude that the slow temporal response of the alpha-adrenergic effector mechanism controlling TPR is the critical element in predicting the observed low-frequency oscillations in ABP and HR.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpheart.1989.256.6.h1573

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 215

Metadata

Authors
Madwed, J. B., Albrecht, P., Mark, R. G., & Cohen, R. J.
Venue
American Journal of Physiology-Heart and Circulatory Physiology
Published
1989-06-01
Volume
256
Issue
6
Pages
H1573-H1579
ISSN
  • 0363-6135 (ISSN-L)
  • 1522-1539
OpenAlex
W2096051767
Cited by
215
References
0
FWCI
1.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Low-frequency oscillations in arterial pressure and heart rate: a simple computer model. https://app.cochat.ai/papers/10.1152/ajpheart.1989.256.6.h1573
The paper
Madwed, J. B., Albrecht, P., Mark, R. G., & Cohen, R. J. (1989). Low-frequency oscillations in arterial pressure and heart rate: a simple computer model. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1989.256.6.h1573

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.