The DOI matches its Crossref record.
A canine model of chronic heart failure produced by multiple sequential coronary microembolizations
Abstract
A canine model of chronic heart failure was produced by multiple sequential intracoronary embolizations with microspheres. Twenty closed-chest dogs underwent three to nine intracoronary embolizations performed 1-3 wk apart. Embolizations were discontinued when left ventricular (LV) ejection fraction was less than 35%. LV ejection fraction was 64 +/- 2% at baseline and decreased to 21 +/- 1% at 3 mo after the last embolization (P less than 0.001). During the same period, LV end-diastolic pressure increased from 6 +/- 1 to 22 +/- 3 mmHg (P less than 0.001); LV end-diastolic volume increased from 64 +/- 3 to 101 +/- 6 6 ml (P less than 0.001), and cardiac output decreased from 2.9 +/- 0.2 to 2.3 +/- 0.1 l/min (P less than 0.01). These changes were accompanied by significant increases of pulmonary artery wedge pressure and systemic vascular resistance. Plasma norepinephrine increased from 332 +/- 17 pg/ml at baseline to 791 +/- 131 pg/ml at 3 mo after the last embolization (P less than 0.01); plasma levels of atrial natriuretic factor increased from 12.7 +/- 10.0 to 28.8 +/- 8.6 pmol/l (P less than 0.01), whereas plasma renin activity remained unchanged. Gross and microscopic postmortem examination showed patchy myocardial fibrosis and LV hypertrophy. We conclude that multiple intracoronary embolizations with microspheres, separated in time, can lead to chronic heart failure in dogs. The preparation is stable and reproducible and manifests many of the sequelae of heart failure that result from loss of contractile myocardium.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Myocardial Substrate Metabolism in the Normal and Failing Heart
Stanley, W. C., Recchia, F. A., & Lopaschuk, G. D. (2005) · Physiological Reviews · doi:10.1152/physrev.00006.2004 · Cited by 2,048
Guidelines for experimental models of myocardial ischemia and infarction
Lindsey, M. L., Bolli, R., Canty, J. M., Du, X.-J., Frangogiannis, N. G., Frantz, S., Gourdie, R. G., Holmes, J. W., Jones, S. P., Kloner, R. A., et al. (2018) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00335.2017 · Cited by 526
Small and large animal models in cardiac contraction research: advantages and disadvantages
Milani-Nejad, N., & Janssen, P. M. L. (2014) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2013.10.007 · Cited by 484
Animal models of human cardiovascular disease, heart failure and hypertrophy
Hasenfuss, G. (1998) · Cardiovascular Research · doi:10.1016/s0008-6363(98)00110-2 · Cited by 441
Animal Models of Heart Failure: A Scientific Statement From the American Heart Association
Houser, S. R., Margulies, K. B., Murphy, A. M., Spinale, F. G., Francis, G. S., Prabhu, S. D., Rockman, H. A., Kass, D. A., Molkentin, J. D., Sussman, M. A., et al. (2012) · Circulation Research · doi:10.1161/res.0b013e3182582523 · Cited by 435
Metadata
- Authors
- Sabbah, H. N., Stein, P. D., Kono, T., Gheorghiade, M., Levine, T. B., Jafri, S., Hawkins, E. T., & Goldstein, S.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1991-04-01
- Volume
- 260
- Issue
- 4
- Pages
- H1379-H1384
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2200860575
- Cited by
- 282
- References
- 0
- FWCI
- 5.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A canine model of chronic heart failure produced by multiple sequential coronary microembolizations. https://app.cochat.ai/papers/10.1152/ajpheart.1991.260.4.h1379
- The paper
- Sabbah, H. N., Stein, P. D., Kono, T., Gheorghiade, M., Levine, T. B., Jafri, S., Hawkins, E. T., & Goldstein, S. (1991). A canine model of chronic heart failure produced by multiple sequential coronary microembolizations. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1991.260.4.h1379
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.