Cited by 66Cardiovascular Health and Disease PreventionHeart Rate Variability and Autonomic ControlNon-Invasive Vital Sign Monitoring

The DOI matches its Crossref record.

Spontaneous diameter oscillations of the radial artery in humans

Open access
Hayoz, D., Tardy, Y., Rutschmann, B., Mignot, J. P., Achakri, H., Feihl, F., Meister, J. J., Waeber, B., Brunner, H. R.·1993·American Journal of Physiology-Heart and Circulatory Physiology

Abstract

In this study we investigated whether there exists a periodic contractile activity of the radial artery, and we evaluated the impact of such an oscillatory behavior on the mechanical properties of this medium-sized muscular vessel. The internal diameter of the right radial artery was measured noninvasively in six healthy male volunteers aged 18–42 yr using a high-precision ultrasonic echo-tracking device. Blood pressure was simultaneously recorded on the same side at the middle finger by photoplethysmography. The electrical activity of the heart was monitored during the entire experiment by electrocardiography. The frequency components of the arterial diameter, blood pressure, and heart rate were obtained using spectral analysis. Under resting conditions, the radial arterial diameter exhibited a spontaneous oscillation with a period ranging from 45 to 70 s and an amplitude of 80 +/- 14 microns (+/- SE). No very low-frequency mode (< or = 0.02 Hz) was identified in either heart rate or blood pressure. These diameter oscillations affected the distensibility-pressure curves acquired simultaneously. Thus the 3–4% oscillatory variation in arterial diameter was paralleled by a 1.5- to 2-fold change in distensibility. These low-frequency oscillations of large arteries seem to be mediated by an intrinsic vascular mechanism.

Overview

Integrity signals

Registry

Crossref · 10.1152/ajpheart.1993.264.6.h2080

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Cerebrospinal fluid flow in perivascular spaces is driven forward by dynamic constriction and enlargement of the cerebral arteries, and thereby the perivascular space volume, rather than a steady perivascular space size.

    “The data so far indicates that CSF flow in the perivascular spaces (PVSs) is driven forward by dynamic constriction and enlargement of the cerebral arteries, and thereby the PVS volume, rather than a steady PVS size27–31.”

Citations

Cited by

Sorted by citations

Metadata

Authors
Hayoz, D., Tardy, Y., Rutschmann, B., Mignot, J. P., Achakri, H., Feihl, F., Meister, J. J., Waeber, B., & Brunner, H. R.
Affiliations
Centre Hospitalier Universitaire Vaudois (CH)
Venue
American Journal of Physiology-Heart and Circulatory Physiology
Published
1993-06-01
Volume
264
Issue
6
Pages
H2080-H2084
ISSN
  • 0363-6135 (ISSN-L)
  • 1522-1539
OpenAlex
W1807824094
Cited by
66
References
0
Citations by year
2026: 1 · 2025: 1 · 2024: 1 · 2019: 1 · 2018: 1 · 2016: 1 · 2015: 2 · 2014: 1 · 2013: 1 · 2012: 3
FWCI
4.37
Type
journal article
Language
en
Open access
Locations
  • American Journal of Physiology-Heart and Circulatory Physiology (publishedVersion)
  • PubMed (publishedVersion)
  • Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion)
  • Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
  • IRIS (submittedVersion)
  • SERVAL (Université de Lausanne) (submittedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
radial artery, arterial distensibility, blood pressure, heart rate
MeSH terms
Adolescent, Adult, Blood Pressure, Compliance, Humans, Male, Oscillometry, Plethysmography, Rest, Ultrasonography, Radial Artery

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review