Evidence for sensing and integration of biological signals by the capillary network
The DOI matches its Crossref record.
Abstract
The aim of this study was to explore the phenomenon first described by Dietrich (Microvasc. Res. 38: 125-135, 1989) in which a local application of norepinephrine (NE) on a capillary can temporarily reduce flow via constriction of the feeding arteriole. Our objectives were to show that this phenomenon of remote response is not limited to vasoconstriction, can be elicited by materials other than NE, shows stimulus-strength dependency, and can be integrated within the capillary network. We used an intravital micropharmacological approach to iontophoretically apply (in mM concentrations in the pipette) NE, acetylcholine (ACh), 5'-N-ethylcarboxamidoadenosine (NECA, adenosine analogue), K+, and H+ on capillaries of the frog sartorius muscle in situ. Responses were measured in terms of changes in velocity of red blood cells (VRBC) in capillaries or in terms of changes in arteriolar diameter. ACh (3 mM) caused significant increases in diameter (from 34 to 37 microns) and in VRBC (from 250 to 340 microns/s, i.e., 36%). NE (3 mM) reduced VRBC by 16%. The magnitude of ACh and NE velocity responses increased with increasing pipette concentration and with increasing iontophoretic current. The ACh response was blocked by a local pretreatment with atropine. NECA, K+, and H+ caused 20-40% increases in VRBC. Dual application of NE on two capillaries fed by the same arteriole resulted in a greater VRBC reduction than for single NE application. Dual application of NE and ACh significantly attenuated the ACh response.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Regulation of Blood Flow in the Microcirculation
SEGAL, S. S. (2005) · Microcirculation · doi:10.1080/10739680590895028 · Cited by 540
Impaired conduction of vasodilation along arterioles in connexin40-deficient mice
de Wit, C., Roos, F., Bolz, S.-S., Kirchhoff, S., Krüger, O., Willecke, K., & Pohl, U. (2000) · Circulation Research · doi:10.1161/01.res.86.6.649 · Cited by 338
Gap Junctions in the Control of Vascular Function
Figueroa, X. F., & Duling, B. R. (2009) · Antioxidants & Redox Signaling · doi:10.1089/ars.2008.2117 · Cited by 294
Regulation of blood flow in the microcirculation: role of conducted vasodilation
Bagher, P., & Segal, S. S. (2011) · Acta Physiologica · doi:10.1111/j.1748-1716.2010.02244.x · Cited by 248
“Subsequent studies of capillaries in the frog sartorius muscle confirmed this behaviour while showing that ACh delivered from a micropipette increased capillary red blood cell velocity along with arteriolar diameter (Song & Tyml 1993).”
BackgroundConducted Vascular Responses: Communication across the Capillary Bed
Collins, D. M., McCullough, W. T., & Ellsworth, M. L. (1998) · Microvascular Research · doi:10.1006/mvre.1998.2076 · Cited by 167
Metadata
- Authors
- Song, H., & Tyml, K.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1993-10-01
- Volume
- 265
- Issue
- 4
- Pages
- H1235-H1242
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2176653381
- Cited by
- 84
- References
- 0
- FWCI
- 2.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evidence for sensing and integration of biological signals by the capillary network. https://app.cochat.ai/papers/10.1152/ajpheart.1993.265.4.h1235
- The paper
- Song, H., & Tyml, K. (1993). Evidence for sensing and integration of biological signals by the capillary network. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1993.265.4.h1235
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.