Dissociation of heart rate variability from parasympathetic tone
The DOI matches its Crossref record.
Abstract
Time and frequency domain measurements of heart rate variability have been used as indexes of parasympathetic tone. This study evaluates the effects of parasympathetic stimulation on these indexes. Ten normal subjects (5 females, 5 males; age 27.4 +/- 5.1 yr) were evaluated in the Clinical Research Center. Five-minute electrocardiographic recordings were obtained at baseline and during 1) combined alpha-adrenergic stimulation with baroreflex-increased cardiac parasympathetic activity produced by phenylephrine infusion; 2) parasympathetic blockade (atropine 0.04 mg/kg); and 3) isolated alpha-adrenergic stimulation produced by phenylephrine infusion after parasympathetic blockade. The infusion rate of phenylephrine was titrated to increase the systolic blood pressure by 20-30 mmHg. Heart rate variability analysis was performed using standard time and frequency domain parameters. Phenylephrine infusion resulted in a decrease in the time domain measures and in the high-frequency power. After parasympathetic blockade, alpha-adrenergic stimulation had no significant effect on the heart rate variability parameters. These findings suggest that the heart rate variability parameters traditionally associated with parasympathetic tone do not always reliably measure parasympathetic tone, since they decrease with baroreflex parasympathetic stimulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Heart rate variability: origins, methods, and interpretive caveats
BERNTSON, G. G., THOMAS BIGGER, J., ECKBERG, D. L., GROSSMAN, P., KAUFMANN, P. G., MALIK, M., NAGARAJA, H. N., PORGES, S. W., SAUL, J. P., STONE, P. H., et al. (1997) · Psychophysiology · doi:10.1111/j.1469-8986.1997.tb02140.x · Cited by 3,962
PORGES, S. W. (1995) · Psychophysiology · doi:10.1111/j.1469-8986.1995.tb01213.x · Cited by 1,624
The LF/HF ratio does not accurately measure cardiac sympatho-vagal balance
Billman, G. E. (2013) · Frontiers in Physiology · doi:10.3389/fphys.2013.00026 · Cited by 1,401
Grossman, P., & Taylor, E. W. (2007) · Biological Psychology · doi:10.1016/j.biopsycho.2005.11.014 · Cited by 1,133
Sympathovagal Balance: A Critical Appraisal
Eckberg, D. L. (1997) · Circulation · doi:10.1161/01.cir.96.9.3224 · Cited by 1,087
Metadata
- Authors
- Goldberger, J. J., Ahmed, M. W., Parker, M. A., & Kadish, A. H.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1994-05-01
- Volume
- 266
- Issue
- 5
- Pages
- H2152-H2157
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W1803616023
- Cited by
- 137
- References
- 0
- FWCI
- 7.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dissociation of heart rate variability from parasympathetic tone. https://app.cochat.ai/papers/10.1152/ajpheart.1994.266.5.h2152
- The paper
- Goldberger, J. J., Ahmed, M. W., Parker, M. A., & Kadish, A. H. (1994). Dissociation of heart rate variability from parasympathetic tone. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1994.266.5.h2152
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.