Role of active changes in venous capacity by the carotid baroreflex: analysis with a mathematical model
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
To elucidate the role of venous capacity active changes in short-term cardiovascular homeostasis, a mathematical model of the carotid-sinus baroreflex system has been developed. In the model the cardiovascular system is represented as the series arrangement of six lumped compartments, which synthesize the fundamental hemodynamic properties of the systemic arterial, systemic venous, pulmonary arterial, and pulmonary venous circulations as well as of the left and right cardiac volumes. Cardiac outputs from the left and right ventricles are computed as a function of both downstream arterial pressure (afterload) and upstream atrial pressure (preload). Four distinct feedback regulatory mechanisms, working on systemic arterial resistance, heart rate, systemic venous unstressed volume, and systemic venous compliance, are assumed to operate on the cardiovascular system in response to carotid sinus pressure changes. All model parameters, both in the cardiovascular system and in feedback regulatory mechanisms, have been assigned on the basis of physiological data now available. The model is used here to simulate the pattern of the main hemodynamic quantities in the short time period (1-2 min) after acute carotid sinus activation in vagotomized subjects. Simulation results indicate that the model can reproduce experimental data quite well, with reference both to open-loop experiments and to an acute blood hemorrhage performed in closed-loop conditions. Moreover, computer simulations indicate that active changes in venous unstressed volume are of primary importance in regulating cardiac output and systemic arterial pressure during activation of the carotid sinus baroreflex.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Circulation: Overall Regulation
Guyton, A. C., Coleman, T. G., & Granger, H. J. (1972) · Annual Review of Physiology · doi:10.1146/annurev.ph.34.030172.000305 · Cited by 870
Cited by
Interaction between carotid baroregulation and the pulsating heart: a mathematical model
Ursino, M. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.275.5.h1733 · Cited by 361
Self-citationMontani, J., & Van Vliet, B. N. (2009) · Experimental Physiology · doi:10.1113/expphysiol.2008.043299 · Cited by 100
Osborn, J. W., Averina, V. A., & Fink, G. D. (2009) · Experimental Physiology · doi:10.1113/expphysiol.2008.043281 · Cited by 53
Averina, V. A., Othmer, H. G., Fink, G. D., & Osborn, J. W. (2012) · The Journal of Physiology · doi:10.1113/jphysiol.2012.228619 · Cited by 41
A mathematical model of salt‐sensitive hypertension: the neurogenic hypothesis
Averina, V. A., Othmer, H. G., Fink, G. D., & Osborn, J. W. (2015) · The Journal of Physiology · doi:10.1113/jphysiol.2014.278317 · Cited by 37
“Lumped parameter models are used on both short time scales, such as the response to haemorrhage, baroreceptor stimulation and postural change (Ursino et al. 1994; Ursino, 1998; Olufsen et al. 2005), and long-term scales such as the G-C model (Guyton et al.”
Method
Metadata
- Authors
- Ursino, M., Antonucci, M., & Belardinelli, E.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1994-12-01
- Volume
- 267
- Issue
- 6
- Pages
- H2531-H2546
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2147890550
- Cited by
- 59
- References
- 1
- FWCI
- 0.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.