Transport in lymphatic capillaries. II. Microscopic velocity measurement with fluorescence photobleaching
Open accessThe DOI matches its Crossref record.
Abstract
Despite its relevance to the physiology of lymph formation and propulsion, the instantaneous flow velocity in single lymphatic capillaries has not been measured to date. The method of fluorescence recovery after photobleaching (FRAP) was adapted for this purpose and used to characterize flow in the lymphatic capillaries in tail skin of anesthetized mice during a constant-pressure intradermal injection of fluorescein isothiocyanate-dextran (mol wt 2 x 10(6). The median lymph flow velocity was 4.7 microns/s, and the velocity magnitude ranged from 0 to 29 microns/s. The direction of flow was generally proximal, but stasis and backflow toward the site of injection was also detected. Evidence for oscillatory flow was detected in some FRAP experiments, and in separate experiments a periodicity of approximately 120 min-1, directly correlated to respiration frequency, was measured by tracking the motion of fluorescent latex microspheres (1 micron diam) introduced into the lymphatic capillary network. The velocity magnitude showed a correlation with duration of infusion but not with distance from injection site. It is speculated that the temporal decay of mean velocity magnitude could be related to the relaxation of local pressure gradients as partially collapsed vessels expand during the infusion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Normalizing Tumor Microenvironment to Treat Cancer: Bench to Bedside to Biomarkers
Jain, R. K. (2013) · Journal of Clinical Oncology · doi:10.1200/jco.2012.46.3653 · Cited by 1,248
Self-citationThe Role of Mechanical Forces in Tumor Growth and Therapy
Jain, R. K., Martin, J. D., & Stylianopoulos, T. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071813-105259 · Cited by 1,044
Self-citationDelivery of molecular and cellular medicine to solid tumors
Jain, R. K. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.09.011 · Cited by 774
Self-citationTransport of Molecules, Particles, and Cells in Solid Tumors
Jain, R. K. (1999) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.1.1.241 · Cited by 691
Self-citationDissecting tumour pathophysiology using intravital microscopy
Jain, R. K., Munn, L. L., & Fukumura, D. (2002) · Nature Reviews Cancer · doi:10.1038/nrc778 · Cited by 595
Self-citation
Metadata
- Authors
- Berk, D. A., Swartz, M. A., Leu, A. J., & Jain, R. K.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1996-01-01
- Volume
- 270
- Issue
- 1
- Pages
- H330-H337
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2135310061
- Cited by
- 87
- References
- 0
- FWCI
- 0.58
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Transport in lymphatic capillaries. II. Microscopic velocity measurement with fluorescence photobleaching. https://app.cochat.ai/papers/10.1152/ajpheart.1996.270.1.h330
- The paper
- Berk, D. A., Swartz, M. A., Leu, A. J., & Jain, R. K. (1996). Transport in lymphatic capillaries. II. Microscopic velocity measurement with fluorescence photobleaching. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1996.270.1.h330
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.