Noninvasive indexes of cardiac systolic and diastolic function in hyperthyroid and senescent mouse
The DOI matches its Crossref record.
Abstract
The mouse is a common model for transgenic manipulation, however, their small size has made hemodynamic study difficult. A noninvasive 10-MHz pulsed Doppler probe was used to measure aortic and mitral flow velocities in anesthetized, intact mice to study the effects of aging and hypethyroidism (induced by thyroxine) one systolic and diastolic cardiac function. In 10 hyperthyroid mice peak aortic velocity (PAV, an index of systolic function) was 34% higher than in 10 control mice (108 +/- 2 vs. 80 +/- 3 cm/s, P < 0.05). The ratio of early to late mitral filling velocity (E/A ratio, an index of diastolic function) was 47% higher (5.6 +/- 0.8 vs. 3.8 +/- 0.2, P < 0.05) in the hyperthyroid mice. In six old (30 mo) mice PAV was similar to eight young (4 mo) mice (73 +/- 3 vs. 75 +/- 3 cm/s), but the E/A ratio was 59% lower (1.8 +/- 0.3 vs. 4.4 +/- 0.4, P < 0.05). Despite a wide range of observed heart rates, the systolic and diastolic parameters of the groups were clearly separated. We conclude that cardiac systolic and diastolic function in mice, measured by pulsed Doppler ultrasound, are similar to larger species both in magnitude and in their response to hyperthyroidism and aging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kurrelmeyer, K. M., Michael, L. H., Baumgarten, G., Taffet, G. E., Peschon, J. J., Sivasubramanian, N., Entman, M. L., & Mann, D. L. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.070036297 · Cited by 440
Self-citationZhang, D., Gaussin, V., Taffet, G. E., Belaguli, N. S., Yamada, M., Schwartz, R. J., Michael, L. H., Overbeek, P. A., & Schneider, M. D. (2000) · Nature Medicine · doi:10.1038/75037 · Cited by 337
Self-citationEchocardiographic assessment of cardiac function in diabetic db/db and transgenic db/db-hGLUT4 mice
Semeniuk, L. M., Kryski, A. J., & Severson, D. L. (2002) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00088.2002 · Cited by 266
“At heart rates 500 beats/min, E and A waves fuse (32); therefore, diastolic function had to be assessed in anesthetized mice (Table 3).”
BackgroundUltrasound Imaging: Principles and Applications in Rodent Research
Cootney, R. W. (2001) · ILAR Journal · doi:10.1093/ilar.42.3.233 · Cited by 183
“Similarly , transmitral flow velocity profiles have been obtained from rats (Forman et al. 1997; Litwin et al. 1994) and mice (Pollick et al. 1995; Taffet et al. 1996).”
BackgroundMethodDelaughter, M. C., Taffet, G. E., Fiorotto, M. L., Entman, M. L., & Schwartz, R. J. (1999) · The FASEB Journal · doi:10.1096/fasebj.13.14.1923 · Cited by 162
“Our method for pulsed Doppler measurements has been described (24).”
MethodSelf-citation
Metadata
- Authors
- Taffet, G. E., Hartley, C. J., Wen, X., Pham, T., Michael, L. H., & Entman, M. L.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1996-06-01
- Volume
- 270
- Issue
- 6
- Pages
- H2204-H2209
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2415665300
- Cited by
- 74
- References
- 0
- FWCI
- 2.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive indexes of cardiac systolic and diastolic function in hyperthyroid and senescent mouse. https://app.cochat.ai/papers/10.1152/ajpheart.1996.270.6.h2204
- The paper
- Taffet, G. E., Hartley, C. J., Wen, X., Pham, T., Michael, L. H., & Entman, M. L. (1996). Noninvasive indexes of cardiac systolic and diastolic function in hyperthyroid and senescent mouse. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1996.270.6.h2204
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.