Arteriolar responses to extracellular ATP in striated muscle
The DOI matches its Crossref record.
Abstract
Blood flow and its distribution must be appropriately regulated to ensure that perfusion is matched to local tissue demands. We investigated the role of ATP in triggering a conducted alteration in arteriolar diameter in the Saran-covered cheek pouch retractor muscle of anesthetized hamsters (n = 60). Vascular responses were observed using in vivo video microscopy upstream from the site of micropressure application of ATP (10(-8)-10(-4) M) either into the lumen or just outside the wall of first- and second-order arterioles. The role of nitric oxide (NO) in the vascular responses to ATP was determined by inhibiting NO synthase activity with N(omega)-nitro-L-arginine methyl ester (L-NAME) with and without coadministration of an excess of L-arginine. Intraluminal application of ATP led to a concentration-dependent vasodilation, which was conducted upstream along the arteriole. The dilatory response was blocked by systemic pretreatment with L-NAME and was maintained in the presence of an excess of L-arginine. In contrast, ATP introduced extraluminally resulted in a conducted vasoconstrictor response that was enhanced by pretreatment with L-NAME. The dilator response to intraluminal ATP, in the context of ATP release from erythrocytes under conditions associated with decreased supply relative to demand, supports a role for the erythrocyte in communicating local tissue needs to the vasculature, enabling the appropriate matching of oxygen supply to demand.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
González-Alonso, J., Olsen, D. B., & Saltin, B. (2002) · Circulation Research · doi:10.1161/01.res.0000044939.73286.e2 · Cited by 331
Erythrocytes: Oxygen Sensors and Modulators of Vascular Tone
Ellsworth, M. L., Ellis, C. G., Goldman, D., Stephenson, A. H., Dietrich, H. H., & Sprague, R. S. (2009) · Physiology · doi:10.1152/physiol.00038.2008 · Cited by 321
Self-citationRed blood cell regulation of microvascular tone through adenosine triphosphate
Dietrich, H. H., Ellsworth, M. L., Sprague, R. S., & Dacey, R. G. (2000) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2000.278.4.h1294 · Cited by 278
Self-citationConducted Vascular Responses: Communication across the Capillary Bed
Collins, D. M., McCullough, W. T., & Ellsworth, M. L. (1998) · Microvascular Research · doi:10.1006/mvre.1998.2076 · Cited by 167
“In addition, applications of a control solution did not induce the oscillatory response, nor had we observed such a response in our previous study on arterioles (McCullough et al., 1997).”
BackgroundMethodResultSelf-citationRed not dead: signaling in and from erythrocytes
Sprague, R. S., Stephenson, A. H., & Ellsworth, M. L. (2007) · Trends in Endocrinology & Metabolism · doi:10.1016/j.tem.2007.08.008 · Cited by 124
Self-citation
Metadata
- Authors
- McCullough, W. T., Collins, D. M., & Ellsworth, M. L.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1997-04-01
- Volume
- 272
- Issue
- 4
- Pages
- H1886-H1891
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2412969964
- Cited by
- 123
- References
- 0
- FWCI
- 1.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Arteriolar responses to extracellular ATP in striated muscle. https://app.cochat.ai/papers/10.1152/ajpheart.1997.272.4.h1886
- The paper
- McCullough, W. T., Collins, D. M., & Ellsworth, M. L. (1997). Arteriolar responses to extracellular ATP in striated muscle. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1997.272.4.h1886
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.