Noninvasive determination of pulse-wave velocity in mice
The DOI matches its Crossref record.
Abstract
Some transgenic mice have abnormal vascular function, but arterial geometry and dynamics are difficult to evaluate. To examine whether ultrasonic velocimetry could be used to determine arterial pulse-wave velocity (PWV) in mice, a custom-made 20-MHz pulsed Doppler instrument was used to obtain blood flow velocity signals from the aortic arch and the abdominal aorta 4 cm downstream. The upstroke (foot) of the velocity wave was timed at each site with respect to the R wave of the electrocardiogram, and PWV was calculated by dividing the separation distance by the difference in R-foot times. Doppler determinations were compared with invasive tonometry, and PWV was altered pharmacologically. It was found that the upstrokes of pressure (by tonometry) and velocity were coincident (+/-1 ms) and that PWV could be calculated by either method on exposed vessels. With the use of Doppler methods, pulse transit time was determined noninvasively with +/-1-ms resolution in 140 of 142 attempts in 82 mice. The calculated PWV in mice ranged from 220 to 850 cm/s with vasodilating anesthetics producing the low values and vasoconstricting agents producing the higher values. Thus PWV can be determined noninvasively in mice, is similar to that in other mammals, and responds as expected to vasoactive agents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Aroor, A. R., Das, N. A., Carpenter, A. J., Habibi, J., Jia, G., Ramirez-Perez, F. I., Martinez-Lemus, L., Manrique-Acevedo, C. M., Hayden, M. R., Duta, C., et al. (2018) · Cardiovascular Diabetology · doi:10.1186/s12933-018-0750-8 · Cited by 179
“Briefly, the transit time method was utilized to determine PWV which is calculated as the difference in arrival times of a Doppler pulse wave at two locations along the aorta at a fixed distance [36].”
MethodNitric oxide synthase inhibition increases aortic stiffness measured by pulse wave velocity in rats
Fitch, R. (2001) · Cardiovascular Research · doi:10.1016/s0008-6363(01)00299-1 · Cited by 172
Soucy, K. G., Ryoo, S., Benjo, A., Lim, H. K., Gupta, G., Sohi, J. S., Elser, J., Aon, M. A., Nyhan, D., Shoukas, A. A., et al. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00138.2006 · Cited by 135
Cheng, S.-L., Behrmann, A., Shao, J.-S., Ramachandran, B., Krchma, K., Bello Arredondo, Y., Kovacs, A., Mead, M., Maxson, R., & Towler, D. A. (2014) · Diabetes · doi:10.2337/db14-0326 · Cited by 77
HZE56Fe-Ion Irradiation Induces Endothelial Dysfunction in Rat Aorta: Role of Xanthine Oxidase
Soucy, K. G., Lim, H. K., Kim, J. H., Oh, Y., Attarzadeh, D. O., Sevinc, B., Kuo, M. M., Shoukas, A. A., Vazquez, M. E., & Berkowitz, D. E. (2011) · Radiation Research · doi:10.1667/rr2598.1 · Cited by 77
Metadata
- Authors
- Hartley, C. J., Taffet, G. E., Michael, L. H., Pham, T. T., & Entman, M. L.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1997-07-01
- Volume
- 273
- Issue
- 1
- Pages
- H494-H500
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2141811264
- Cited by
- 109
- References
- 0
- FWCI
- 0.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive determination of pulse-wave velocity in mice. https://app.cochat.ai/papers/10.1152/ajpheart.1997.273.1.h494
- The paper
- Hartley, C. J., Taffet, G. E., Michael, L. H., Pham, T. T., & Entman, M. L. (1997). Noninvasive determination of pulse-wave velocity in mice. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1997.273.1.h494
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.