Abstract

Some transgenic mice have abnormal vascular function, but arterial geometry and dynamics are difficult to evaluate. To examine whether ultrasonic velocimetry could be used to determine arterial pulse-wave velocity (PWV) in mice, a custom-made 20-MHz pulsed Doppler instrument was used to obtain blood flow velocity signals from the aortic arch and the abdominal aorta 4 cm downstream. The upstroke (foot) of the velocity wave was timed at each site with respect to the R wave of the electrocardiogram, and PWV was calculated by dividing the separation distance by the difference in R-foot times. Doppler determinations were compared with invasive tonometry, and PWV was altered pharmacologically. It was found that the upstrokes of pressure (by tonometry) and velocity were coincident (+/-1 ms) and that PWV could be calculated by either method on exposed vessels. With the use of Doppler methods, pulse transit time was determined noninvasively with +/-1-ms resolution in 140 of 142 attempts in 82 mice. The calculated PWV in mice ranged from 220 to 850 cm/s with vasodilating anesthetics producing the low values and vasoconstricting agents producing the higher values. Thus PWV can be determined noninvasively in mice, is similar to that in other mammals, and responds as expected to vasoactive agents.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpheart.1997.273.1.h494

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 109

Metadata

Authors
Hartley, C. J., Taffet, G. E., Michael, L. H., Pham, T. T., & Entman, M. L.
Venue
American Journal of Physiology-Heart and Circulatory Physiology
Published
1997-07-01
Volume
273
Issue
1
Pages
H494-H500
ISSN
  • 0363-6135 (ISSN-L)
  • 1522-1539
OpenAlex
W2141811264
Cited by
109
References
0
FWCI
0.46
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Noninvasive determination of pulse-wave velocity in mice. https://app.cochat.ai/papers/10.1152/ajpheart.1997.273.1.h494
The paper
Hartley, C. J., Taffet, G. E., Michael, L. H., Pham, T. T., & Entman, M. L. (1997). Noninvasive determination of pulse-wave velocity in mice. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1997.273.1.h494

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.