The DOI matches its Crossref record.
In vivo murine left ventricular pressure-volume relations by miniaturized conductance micromanometry
Abstract
The mouse is the species of choice for creating genetically engineered models of human disease. To study detailed systolic and diastolic left ventricular (LV) chamber mechanics in mice in vivo, we developed a miniaturized conductance-manometer system. α-Chloralose-urethan-anesthetized animals were instrumented with a two-electrode pressure-volume catheter advanced via the LV apex to the aortic root. Custom electronics provided time-varying conductances related to cavity volume. Baseline hemodynamics were similar to values in conscious animals: 634 ± 14 beats/min, 112 ± 4 mmHg, 5.3 ± 0.8 mmHg, and 11,777 ± 732 mmHg/s for heart rate, end-systolic and end-diastolic pressures, and maximum first derivative of ventricular pressure with respect to time (dP/d t max), respectively. Catheter stroke volume during preload reduction by inferior vena caval occlusion correlated with that by ultrasound aortic flow probe ( r 2= 0.98). This maneuver yielded end-systolic elastances of 79 ± 21 mmHg/μl, preload-recruitable stroke work of 82 ± 5.6 mmHg, and slope of dP/d t max-end-diastolic volume relation of 699 ± 100 mmHg ⋅ s−1⋅ μl−1, and these relations varied predictably with acute inotropic interventions. The control normalized time-varying elastance curve was similar to human data, further supporting comparable chamber mechanics between species. This novel approach should greatly help assess cardiovascular function in the blood-perfused murine heart.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pacher, P., Nagayama, T., Mukhopadhyay, P., Bátkai, S., & Kass, D. A. (2008) · Nature Protocols · doi:10.1038/nprot.2008.138 · Cited by 734
Self-citationAnimal Models of Heart Failure: A Scientific Statement From the American Heart Association
Houser, S. R., Margulies, K. B., Murphy, A. M., Spinale, F. G., Francis, G. S., Prabhu, S. D., Rockman, H. A., Kass, D. A., Molkentin, J. D., Sussman, M. A., et al. (2012) · Circulation Research · doi:10.1161/res.0b013e3182582523 · Cited by 435
Self-citationBarouch, L. A., Berkowitz, D. E., Harrison, R. W., O’Donnell, C. P., & Hare, J. M. (2003) · Circulation · doi:10.1161/01.cir.0000083716.82622.fd · Cited by 341
Self-citationEchocardiographic assessment of cardiac function in diabetic db/db and transgenic db/db-hGLUT4 mice
Semeniuk, L. M., Kryski, A. J., & Severson, D. L. (2002) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00088.2002 · Cited by 266
Schmidt, U., del Monte, F., Miyamoto, M. I., Matsui, T., Gwathmey, J. K., Rosenzweig, A., & Hajjar, R. J. (2000) · Circulation · doi:10.1161/01.cir.101.7.790 · Cited by 230
Metadata
- Authors
- Georgakopoulos, D., Mitzner, W. A., Chen, C.-H., Byrne, B. J., Millar, H. D., Hare, J. M., & Kass, D. A.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1998-04-01
- Volume
- 274
- Issue
- 4
- Pages
- H1416-H1422
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2145570802
- Cited by
- 253
- References
- 0
- FWCI
- 6.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vivo murine left ventricular pressure-volume relations by miniaturized conductance micromanometry. https://app.cochat.ai/papers/10.1152/ajpheart.1998.274.4.h1416
- The paper
- Georgakopoulos, D., Mitzner, W. A., Chen, C.-H., Byrne, B. J., Millar, H. D., Hare, J. M., & Kass, D. A. (1998). In vivo murine left ventricular pressure-volume relations by miniaturized conductance micromanometry. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.1998.274.4.h1416
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.