The DOI matches its Crossref record.
Capillary endothelial surface layer selectively reduces plasma solute distribution volume
Abstract
We previously reported that a 0.4- to 0.5-μm-thick endothelial surface layer confines Dextran 70 (70 kDa) to the central core of hamster cremaster muscle capillaries. In the present study we used a variety of plasma tracers to probe the barrier properties of the endothelial surface layer using combined fluorescence and brightfield intravital microscopy. No permeation of the endothelial surface layer was observed for either neutral or anionic dextrans ≥70 kDa, but a neutral Dextran 40 (40 kDa) and neutral free dye (rhodamine, 0.4 kDa) equilibrated with the endothelial surface layer within 1 min. In contrast, small anionic tracers of similar size (0.4–40 kDa) permeated the endothelial surface layer relatively slowly with half-times (τ 50) between 11 and 60 min, depending on tracer size. Furthermore, two plasma proteins, fibrinogen (340 kDa) and albumin (67 kDa), moved slowly into the endothelial surface layer at the same rates, despite greatly differing sizes (τ 50 ≈ 40 min). Dextran 70, which did not enter the glycocalyx over the course of these experiments, entered at the same rate as free albumin when it was conjugated to albumin. These findings demonstrate that for anionic molecules size and charge have a profound effect on the penetration rate into the glycocalyx. The equal rates of penetration of the glycocalyx demonstrated by the different protein molecules suggests that multiple factors may influence the penetration of the barrier, including molecular size, charge, and structure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Molecular basis of the effects of shear stress on vascular endothelial cells
Li, Y.-S. J., Haga, J. H., & Chien, S. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.09.030 · Cited by 904
Klaassen, I., Van Noorden, C. J. F., & Schlingemann, R. O. (2013) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2013.02.001 · Cited by 722
Microvascular Rheology and Hemodynamics
LIPOWSKY, H. H. (2005) · Microcirculation · doi:10.1080/10739680590894966 · Cited by 414
Endothelial permeability, LDL deposition, and cardiovascular risk factors—a review
Mundi, S., Massaro, M., Scoditti, E., Carluccio, M. A., van Hinsbergh, V. W. M., Iruela-Arispe, M. L., & De Caterina, R. (2018) · Cardiovascular Research · doi:10.1093/cvr/cvx226 · Cited by 367
Bruegger, D., Jacob, M., Rehm, M., Loetsch, M., Welsch, U., Conzen, P., & Becker, B. F. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00218.2005 · Cited by 265
Metadata
- Authors
- Vink, H., & Duling, B. R.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2000-01-01
- Volume
- 278
- Issue
- 1
- Pages
- H285-H289
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2162551249
- Cited by
- 335
- References
- 0
- FWCI
- 4.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Capillary endothelial surface layer selectively reduces plasma solute distribution volume. https://app.cochat.ai/papers/10.1152/ajpheart.2000.278.1.h285
- The paper
- Vink, H., & Duling, B. R. (2000). Capillary endothelial surface layer selectively reduces plasma solute distribution volume. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.2000.278.1.h285
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.