Accuracy of echocardiographic estimates of left ventricular mass in mice
The DOI matches its Crossref record.
Abstract
Genetically modified mice have created the need for accurate noninvasive left ventricular mass (LVM) measurements. Recent technical advances provide two-dimensional images adequate for LVM calculation using the area-length method, which in humans is more accurate than M-mode methods. We compared the standard M-mode and area-length methods in mice over a wide range of LV sizes and weights (62–210 mg). Ninety-one CD-1 mice (38 normal, 44 aortic banded, and 9 inherited dilated cardiomyopathy) were imaged transthoracically (15 MHz linear transducer, 120 Hz). Compared with necropsy weights, area-length measurements showed higher correlation than the M-mode method ( r = 0.92 vs. 0.81), increased accuracy (bias ± SD: 1.4 ± 27.1% vs. 36.7 ± 51.6%), and improved reproducibility. There was no significant difference between end-systolic and end-diastolic estimates. The truncated ellipsoid estimation produced results similar in accuracy to the area-length method. Whereas current echocardiographic technology can accurately and reproducibly estimate LVM with the two-dimensional, area-length formula in a variety of mouse models, additional technological improvements, rather than refinement of geometric models, will likely improve the accuracy of this methodology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Askari, A. T., Unzek, S., Popovic, Z. B., Goldman, C. K., Forudi, F., Kiedrowski, M., Rovner, A., Ellis, S. G., Thomas, J. D., DiCorleto, P. E., et al. (2003) · The Lancet · doi:10.1016/s0140-6736(03)14232-8 · Cited by 1,270
IL-33 and ST2 comprise a critical biomechanically induced and cardioprotective signaling system
Sanada, S., Hakuno, D., Higgins, L. J., Schreiter, E. R., McKenzie, A. N. J., & Lee, R. T. (2007) · Journal of Clinical Investigation · doi:10.1172/jci30634 · Cited by 1,044
Impact of anesthesia on cardiac function during echocardiography in mice
Roth, D. M., Swaney, J. S., Dalton, N. D., Gilpin, E. A., & Ross, J. (2002) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00845.2001 · Cited by 346
Metabolic stress–induced activation of FoxO1 triggers diabetic cardiomyopathy in mice
Battiprolu, P. K., Hojayev, B., Jiang, N., Wang, Z. V., Luo, X., Iglewski, M., Shelton, J. M., Gerard, R. D., Rothermel, B. A., Gillette, T. G., et al. (2012) · Journal of Clinical Investigation · doi:10.1172/jci60329 · Cited by 345
Intensity-controlled treadmill running in mice: cardiac and skeletal muscle hypertrophy
Kemi, O. J., Loennechen, J. P., Wisløff, U., & Ellingsen, Ø. (2002) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00231.2002 · Cited by 299
Metadata
- Authors
- Collins, K. A., Korcarz, C. E., Shroff, S. G., Bednarz, J. E., Fentzke, R. C., Lin, H., Leiden, J. M., & Lang, R. M.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2001-05-01
- Volume
- 280
- Issue
- 5
- Pages
- H1954-H1962
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W193564708
- Cited by
- 111
- References
- 0
- FWCI
- 5.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy of echocardiographic estimates of left ventricular mass in mice. https://app.cochat.ai/papers/10.1152/ajpheart.2001.280.5.h1954
- The paper
- Collins, K. A., Korcarz, C. E., Shroff, S. G., Bednarz, J. E., Fentzke, R. C., Lin, H., Leiden, J. M., & Lang, R. M. (2001). Accuracy of echocardiographic estimates of left ventricular mass in mice. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.2001.280.5.h1954
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.