Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 246

The DOI matches its Crossref record.

Shear level influences resistance artery remodeling: wall dimensions, cell density, and eNOS expression

Tuttle, Jay L., Nachreiner, Ryan D., Bhuller, Amardip S., Condict, Kevin W., Connors, Bret A., Herring, B. Paul, Dalsing, Michael C., Unthank, Joseph L.·2001·American Journal of Physiology-Heart and Circulatory Physiology

Abstract

The magnitude of shear stimulus has been shown to determine the level of growth factor expression in cell culture. However, little is known regarding what effect shear level has on specific arterial wall remodeling events in vivo. We have hypothesized that the rate of luminal diameter change and specific remodeling events within the arterial wall layers are dependent on shear level. Selective ligations were made to alter the number of microvascular perfusion units of mesenteric arteries within the same animal to ∼50%, 200%, and 400% of control. Arterial blood flow and wall shear rate were correlated with the degree of alteration in perfusion units. Luminal diameters were decreased in 50% arteries by day 2 and increased ∼17% and 33%, respectively, in 200% and 400% arteries at day 7. The rate of diameter change was greatest in 50% and 400% arteries. Wall areas (medial +37%; intimal +18% at day 2) and cell densities (intimal +26%; adventitial +44% at day 2) were altered only in the 400% arteries. A positive correlation existed by day 2between endothelial staining for endothelial nitric oxide synthase and shear level. The results demonstrate that shear level influences the rate of luminal expansion, specific remodeling events within each wall layer, and the degree of endothelial gene expression. A greater understanding of how shear level influences specific remodeling events within each wall layer should aid in the development of targeted therapies to manipulate the remodeling process in health and disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpheart.2001.281.3.h1380

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 246

Metadata

Authors
Tuttle, J. L., Nachreiner, R. D., Bhuller, A. S., Condict, K. W., Connors, B. A., Herring, B. P., Dalsing, M. C., & Unthank, J. L.
Venue
American Journal of Physiology-Heart and Circulatory Physiology
Published
2001-09-01
Volume
281
Issue
3
Pages
H1380-H1389
ISSN
  • 0363-6135 (ISSN-L)
  • 1522-1539
OpenAlex
W2341372857
Cited by
246
References
0
FWCI
7.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Shear level influences resistance artery remodeling: wall dimensions, cell density, and eNOS expression. https://app.cochat.ai/papers/10.1152/ajpheart.2001.281.3.h1380
The paper
Tuttle, J. L., Nachreiner, R. D., Bhuller, A. S., Condict, K. W., Connors, B. A., Herring, B. P., Dalsing, M. C., & Unthank, J. L. (2001). Shear level influences resistance artery remodeling: wall dimensions, cell density, and eNOS expression. American Journal of Physiology-Heart and Circulatory Physiology. https://doi.org/10.1152/ajpheart.2001.281.3.h1380

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.