CoChat

Myosin heavy chain gene expression changes in the diaphragm of patients with chronic lung hyperinflation

Mercadier, Jean-Jacques, Schwartz, Ketty, Schiaffino, Stefano, Wisnewsky, Claudine, Ausoni, Simonetta, Heimburger, Michèle, Marrash, Rolana, Pariente, René, Aubier, Michel · 1998 · American Journal of Physiology-Lung Cellular and Molecular Physiology
Cited by 78

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

In striated muscle, chronic increases in workload result in changes in myosin phenotype. The aim of this study was to determine whether such changes occur in the diaphragm of patients with severe chronic obstructive pulmonary disease, a situation characterized by a chronic increase in respiratory load and lung volume. Diaphragm biopsies were obtained from 22 patients who underwent thoracic surgery. Myosin was characterized with electrophoresis in nondenaturing conditions, SDS-glycerol PAGE, and Western blotting with monoclonal antibodies specific for slow and fast myosin heavy chain (MHC) isoforms. Flow volume curves, total lung capacity, and functional residual capacity were measured before surgery in 20 patients. We found that the human diaphragm is composed of at least four myosin isoforms, one slow and three fast, resulting from the combination of three MHC species. Chronic overload was associated with an increase in the slow β-MHC species at the expense of the fast species (β-MHC, 78.2 ± 4.6 and 50.0 ± 6.5% in emphysematous and control patients, respectively; P < 0.005). Linear correlations were found between β-MHC percentage and forced expiratory volume in 1 s ( r = −0.52; P < 0.02), total lung capacity ( r = 0.44; P < 0.05), and functional residual capacity ( r = 0.65; P < 0.003). The human adult diaphragm is composed of a balanced proportion of slow and fast myosin isoforms. In patients with chronic obstructive pulmonary disease, the proportion of fast myosins decreases, whereas that of slow myosin increases. This increase appears to be closely related to lung hyperinflation and may reflect an adaptation of the diaphragm to the new functional requirements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajplung.1998.274.4.l527

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 78

Metadata

Authors
Mercadier, J.-J., Schwartz, K., Schiaffino, S., Wisnewsky, C., Ausoni, S., Heimburger, M., Marrash, R., Pariente, R., & Aubier, M.
Venue
American Journal of Physiology-Lung Cellular and Molecular Physiology
Published
1998-04-01
Volume
274
Issue
4
Pages
L527-L534
ISSN
  • 1040-0605 (ISSN-L)
  • 1522-1504
OpenAlex
W2189324590
Cited by
78
References
2
FWCI
1.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.