Comparative NMR and NIRS analysis of oxygen-dependent metabolism in exercising finger flexor muscles
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Muscle contraction requires the physiology to adapt rapidly to meet the surge in energy demand. To investigate the shift in metabolic control, especially between oxygen and metabolism, researchers often depend on near-infrared spectroscopy (NIRS) to measure noninvasively the tissue O 2. Because NIRS detects the overlapping myoglobin (Mb) and hemoglobin (Hb) signals in muscle, interpreting the data as an index of cellular or vascular O 2 requires deconvoluting the relative contribution. Currently, many in the NIRS field ascribe the signal to Hb. In contrast,1 H NMR has only detected the Mb signal in contracting muscle, and comparative NIRS and NMR experiments indicate a predominant Mb contribution. The present study has examined the question of the NIRS signal origin by measuring simultaneously the 1 H NMR,31 P NMR, and NIRS signals in finger flexor muscles during the transition from rest to contraction, recovery, ischemia, and reperfusion. The experiment results confirm a predominant Mb contribution to the NIRS signal from muscle. Given the NMR and NIRS corroborated changes in the intracellular O 2, the analysis shows that at the onset of muscle contraction, O 2 declines immediately and reaches new steady states as contraction intensity rises. Moreover, lactate formation increases even under quite aerobic condition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Biochemistry of exercise-induced metabolic acidosis
Robergs, R. A., Ghiasvand, F., & Parker, D. (2004) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00114.2004 · Cited by 1,304 · cited 1×
“contribution of glycolysis to the observed metabolic acidosis, remains a controversial and heated topic of debate (81).”
BackgroundMyoglobin O2 desaturation during exercise. Evidence of limited O2 transport.
Richardson, R. S., Noyszewski, E. A., Kendrick, K. F., Leigh, J. S., & Wagner, P. D. (1995) · Journal of Clinical Investigation · doi:10.1172/jci118237 · Cited by 647 · cited 1×
“However, at all MVC steps (25%, 50%, 75%, and 90%), the reported DMb signal intensity remains constant at a plateau value of 50% of maximum DMb (79, 80).”
BackgroundFerrari, M., Muthalib, M., & Quaresima, V. (2011) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2011.0230 · Cited by 450
Arnold, D. L., Matthews, P. M., & Radda, G. K. (1984) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910010303 · Cited by 442
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Wilson, J. R., Mancini, D. M., McCully, K., Ferraro, N., Lanoce, V, & Chance, B. (1989) · Circulation · doi:10.1161/01.cir.80.6.1668 · Cited by 256 · cited 3×
“(97) detected no difference in the NIRS response and concluded that Mb did not contribute to the NIRS signal.”
BackgroundMethodCostes, F., Barthelemy, J. C., Feasson, L., Busso, T., Geyssant, A., & Denis, C. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.80.4.1345 · Cited by 101 · cited 2×
“venous O2 measurement to implicate the Hb origin of the NIRS signal (27, 97).”
Background
Cited by
The Science and Translation of Lactate Shuttle Theory
Brooks, G. A. (2018) · Cell Metabolism · doi:10.1016/j.cmet.2018.03.008 · Cited by 1,486
“During exercise at about 65% of maximal oxygen consumption (VO2max), net lactate production and release fromworking muscle beds rise with a corresponding increase in L/P more than an order of magnitude (to 500), but the intramuscular PO2 remains at 3–4 Torr, well above the critical mitochondrial O2 level (Bendahan et…”
BackgroundInfluentialLactate as a fulcrum of metabolism
Brooks, G. A. (2020) · Redox Biology · doi:10.1016/j.redox.2020.101454 · Cited by 724
Understanding near infrared spectroscopy and its application to skeletal muscle research
Barstow, T. J. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00166.2018 · Cited by 470
Hypoxia induces mitochondrial protein lactylation to limit oxidative phosphorylation
Mao, Y., Zhang, J., Zhou, Q., He, X., Zheng, Z., Wei, Y., Zhou, K., Lin, Y., Yu, H., Zhang, H., et al. (2024) · Cell Research · doi:10.1038/s41422-023-00864-6 · Cited by 359
Muscle Oximetry in Sports Science: A Systematic Review
Perrey, S., & Ferrari, M. (2018) · Sports Medicine · doi:10.1007/s40279-017-0820-1 · Cited by 220
“Recent studies carried out on NIRS in combination with (1)H-magnetic resonance spectroscopy, aiming at distinguishing between Hb and Mb desaturation during ischemia and exercise, have confirmed a predominant Mb contribution to the muscle NIRS signal [4].”
Background
Metadata
- Authors
- Bendahan, D., Chatel, B., & Jue, T.
- Venue
- American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
- Publisher
- American Physiological Society
- Published
- 2017-12-01
- Volume
- 313
- Issue
- 6
- Pages
- R740-R753
- ISSN
- 0363-6119 (ISSN-L)
- 1522-1490
- OpenAlex
- W2751697640
- Cited by
- 47
- References
- 8
- FWCI
- 5.42
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.